Chengdu Ebyte Electronic Technology Co.,Ltd
E07-400M10S User Manual
Copyright ©2012–2021,Chengdu Ebyte Electronic Technology Co.,Ltd.
55
Health care products;
Advanced Meter Reading Architecture(AMI);
Automotive industry applications.
2 Specification and Parameter
2.1 Limit Parameter
Main parameter
Performance
Remark
Min
Max
Power supply
(
V
)
0
3.6
Voltage over 3.6V will cause permanent damage to
module
Blocking power
(
dBm
)
-
10
Chances of burn is slim when modules are used in
short distance
Operating temperature
(
℃
)
-40
+85
Industrial grade
2.2 Operating Parameter
Main parameter
Performance
Remark
Min
Typical
Max
Operating voltage
(
V
)
1.8
3.3
3.6
3.3 V ensures output power
Communication level
(
V
)
-
3.3
-
For 5V TTL, it may be at risk of burning down
Operating temperature
(
℃
)
-40
-
+85
Industrial grade
Operating frequency
(
MHz
)
410
433
450
Support ISM band
Power
Consump
- tion
TX current
(
mA
)
-
35
-
Instant power consumption
RX current
(
mA
)
-
18
-
-
Sleep current
(
μA
)
-
0.6
-
Shut down by software
Max TX power
(
dBm
)
9.5
10
11
-
Receiving sensitivity
(
dBm
)
-107
-108
-109
Air data rate is 1.2kbps
Air data rate
(
bps
)
0.6k
-
500k
Controlled via user’s programming
Main parameter
Description
Remark
Reference distance
1.5km
Test condition
:
clear and open area, antenna gain: 5dBi
,
antenna height: 2.5m
,
air data rate: 1.2kbps
FIFO
64Byte
Maximum length of a single transmission
Crystal Oscillator
26MHz
10ppm
Modulation
GFSK(recommended) Support OOK
、
ASK
、
GFSK
、
2-FSK
、
4-FSK and MSK