Chengdu Ebyte Electronic Technology Co., Ltd.

E01-2G4M13S User Manual

Copyright ©2012–2018,Chengdu Ebyte Electronic Technology Co.,Ltd

2

1.3 Application

Home security alarm and remote keyless entry;

Smart home and industrial sensors;

Wireless alarm security system;

Building automation solutions;

Wireless industrial-grade remote control;

Health care products;

Advanced Meter Reading Architecture(AMI);

Automotive industry applications.

2 Specification and parameter

2.1 Limit parameter

Main parameter

Performance

Remark

Min.

Max.

Power supply(V)

0

3.6

Voltage over 3.6V will cause permanent

damage to module

Blocking power(dBm)

-

10

Chances of burn is slim when modules

are used in short distance

Operating temperature(℃)

-40

85

/

2.2 Operating parameter

Main parameter

Performance

Remark

Min.

Typ.

Max.

Operating voltage(V)

2.0

3.3

3.6

≥3.3 V ensures output power

Communication level(V)

3.3

For 5V TTL, it may be at risk of burning

down

Operating temperature(℃)

-40

25

85

Industrial design

Operating frequency(MHz)

2.4

-

2.525

Support ISM band

Power
consump
tion

TX current(mA)

-

38

-

Instant power consumption

RX current(mA)

-

16.8

-

Sleep current (μA)

-

1.2

-

Software is shut down

Max Tx power(dBm)

12.5

13

13.5

Receiving sensitivity(dBm)

-97

-98

-99

Air data rate is 250 kbps

Air data rate(bps)

250k

250k

2M

Controlled via user’s programming

Summary of Contents for E01-2G4M13S

Page 1: ...E01 2G4M13S User Manual NRF24L01P 2 4GHz SMD Wireless Module...

Page 2: ...e real use scenario and the difference is very obvious Industrial grade high precision 16MHz crystal is used This product has obtained domestic and international authoritative certification such as FC...

Page 3: ...e over 3 6V will cause permanent damage to module Blocking power dBm 10 Chances of burn is slim when modules are used in short distance Operating temperature 40 85 2 2 Operating parameter Main paramet...

Page 4: ...nce for reference 800m Test condition clear and open area antenna gain 5dBi antenna height 2 5m air data rate 250kbps FIFO 32 Bytes Max Transmitting length per packet Crystal frequency 16MHz Modulatio...

Page 5: ...be fluctuated frequently When designing the power supply circuit for the module it is often recommended to reserve more than 30 of the margin so the whole machine is beneficial for long term stable o...

Page 6: ...4 2 Software editing Insert the module on the user s circuit board use the microcontroller to communicate with the module via SPI or serial port and operate the control register and the transceiver bu...

Page 7: ...ken when installing and using high frequency devices have electrostatic susceptibility Please ensure the humidity is within limited range some parts are sensitive to humidity Please avoid using module...

Page 8: ...m km E01 ML01S nRF24L01P 2 4G 0 0 1 SMD PCB E01 ML01D nRF24L01P 2 4G 0 0 1 DIP PCB E01 ML01IPX nRF24L01P 2 4G 0 0 2 SMD IPEX E01 2G4M13S nRF24L01P 2 4G 13 0 8 SMD PCB E01 ML01DP4 nRF24L01P 2 4G 20 1 8...

Page 9: ...ion Date Description Issued by 1 00 2018 11 15 Initial version huaa About us Technical support support cdebyte com Documents and RF Setting download link www ebyte com Thank you for using Ebyte produc...

Reviews: