Chengdu Ebyte Electronic Technology Co., Ltd.
Copyright ©2012–2019, Chengdu Ebyte Electronic Technology Co.,Ltd
13
1
DO 5
Relay 5 output
indication
Green LED, NO 5, COM 5 are closed
2
DO 6
Relay 6 output
indication
Green LED, NO 6, COM 6 is on and off
3
DI 1
Digital input
channel 1 indication
Green LED, DI 1, DIG shorted up
4
DI 2
Digital input
channel 2 indication
Green LED, DI 2, DIG shorted up
5
DI 3
Digital input
channel 3 indication
Green LED, DI 3, DIG shorted up
6
DI 4
Digital input
channel 4 indication
Green LED, DI 4, DIG short-circuited
7
DI 5
Digital input
channel 5 indication
Green LED, DI 5, DIG short-circuited
8
DI 6
Digital input
channel 6 indication
Green LED, DI 6, DIG shorted up
9
DO 1
Relay 1 output
indication
Green LED, NO 1 and COM 1 are on and off
10
DO 2
Relay 2 output
indication
Green LED, NO 2, COM 2 is on and off
11
DO 3
Relay 3 output
indication
Green LED, NO 3, COM 3 are closed
12
DO 4
Relay 4 output
indication
Green LED, NO 4, COM 4 are closed
13
NET
Network indication
Yellow LED, long after entering the network
14
DATA
Serial data
indication
Yellow LED, RS485 interface lights up when data is
transmitted (expressively flashes)
15
WORK
Work/reset
indication
Yellow LED, flashing regularly / flashing after
successful reset
16
PWR
Power indicator
Red LED, long bright
Note: Grounding: It is recommended to connect the housing to the ground
2.3 Reload touch button description
Long press 5S is valid, after the reset is successful, the WORK lamp flashes quickly, and the Modbus device address,
RS485 serial port baud rate and check digit are restored to the factory settings.