Chengdu Ebyte Electronic Technology Co.,Ltd.
Copyright ©2012–2021
,
Chengdu Ebyte Electronic Technology Co.,Ltd.
20
parameter
Returns the
value
description
example
AT+CCLASS=2
OK
Precaution
s
Before Join needs to set, the default is classA
Command
character
The
command
type
The command format
response
CSTAUS
(Query
the
current state
of the device).
Test
command
AT+CSTAUS=?
+CSTATUS:
”
status
”
OK
Query
command
AT+CSTATUS?
+CSTATUS:<status>
OK
The
description
of the
parameter
<status>
:
00 - No data operation
01 - Data sent
02 - Data delivery failed
03 - Data sent successfully
04 - JOIN success (only in the first JOIN process)
05 - JOIN failure (only in the first JOIN process)
06 - Network May Be Abnormal (Link Check Results)
07 - Send data successfully, no downstream
08 - Send data successfully, with a downstream
Returns the
value
description
example
AT+CSTATUS?
+CSTATUS=03
OK
Precautions Query the current state of the device
Command
character
The
command
type
The command format
response
CJOIN
(Set
Join).
Test
command
AT+CJOIN=?
+CJOIN:<ParaTag1>,[ParaTag2],
…
[ParaTag4
]
OK
Query
command
AT+CJOIN?
+CJOIN:<ParaValue1>,[ParaValue2],
...
[Para
Value4]
OK
Set the
command
AT+CJOIN=<ParaValue1>
,
[ParaValue2],….
[ParaValue4]
If the input is legal, first return OK, then start
automatic
authentication, return authentication results.
CJOIN: OK Authentication Success
- CJOIN: FAIL Authentication Failed