the SN value is a hexadecimal ASCII value.
40182
(
0x00B5)
40183
(
0x00B6) --40192(0x00BF)
SN length
SN value
00 10
31 38 31 31 30 31 31 39 34 32 32 38 42 30 32 37
4.4.8 Read base station location LBS
The base station location register read start address is 40193 (0x00C0), and the total length of the register
is 20. The first register is the base station location information length, and the second register to the twentieth
register stores the base station location value in the . For example, the base station location value LAC: 812F,
CID: 8056B08, the corresponding register value is as follows. In the register, the base station location value is a
hexadecimal ASCII value.
40193
(
0x00C0)
40194
(
0x00C1) --40213(0x00D4)
Base station location register length
Base station location register
00 14
4C 41 43 3A 38 31 32 46 2C 43 49 44 3A 38 30 35 36 42 30 38