Chengdu Ebyte Electronic Technology Co,;Ltd E70 -DTU (433NW30) user manual
Copyright ©2012–2019,Chengdu Ebyte Electronic Technology Co,;Ltd
13
AT+RSCFG=?
Description:
Gets the reboot parameter configuration
Response
:
RSCFG:0
AT+RSCFG=Value
Description:
Value
:
0 or 60~65535
(
S
)
When the value less than 60s, the system judges 60, equals 0s, does not restart
Example
:
AT+RSCFG=0
Note: This parameter can be used for node disconnection detection. It is recommended to open it.
12
AT+UBCFG Setting /Querying the baud rate parameter (reboot valid)
AT+UBCFG=?
Description
:
Obtains the baud rate parameter
Response
:
UBCFG:7
AT+UBCFG=Value
Description
:
Value:0~7
0
:
1200
1
:
2400
2
:
4800
3
:
9600
4
:
19200
5
:
38400
6
:
57600
7
:
115200
Example
:
AT+UBCFG=7
13
AT+UPCFG Setting /Querying the device parity parameter(reboot valid)
AT+UPCFG=?
Description
Gets the device parity parameter
Response
:
UPCFG:0
AT+UPCFG=Value
Description
:
Value:0~2
0
:
None
1
:
Odd parity
2
:
Even parity
Example
:
AT+UPCFG=0
14
AT+PWCFG Setting /Querying the power parameter(reboot valid)
AT+PWCFG=?
Description
:
Gets the power parameter
Response
:
PWCFG:3
AT+PWCFG=Value
Description
:
Value:0~3
0
:
Polar Altitude
1
:
High
2
:
Medium
3
:
Low
Example
:
AT+ PWCFG=3
15
AT+IOCFG Setting /Querying the IO parameter
AT+IOCFG=?
Description
:
Gets the IO parameter
Response
:
IOCFG:0
AT+IOCFG=Value
Description
:
Value
:
0 or 1
0
:
Push-pull
1
:
open-drain