command start address
length
parameter
Transmit
:
C2
05
01
09
Return
:
C1
05
01
09
Example 2
:
set module address
(
0x1234
)
, network address (0x00), UART (9600
8N1), air data rate (1.2K)
Transmit
:
C2 00 04 12 34 00 61
Return
:
C1 00 04 12 34 00 61
5
Wireless
configuration
Command
:
CF CF + general command
Reply
:
CF CF + general response
Example 1
:
set channel as 0x09
wireless command head command start address
length
parameter
Transmit
:
CF CF
C0
05
01
09
Return
:
CF CF
C1
05
01
09
Example 2
:
set module address
(
0x1234
)
, network address(0x00), UART(9600
8N1), air data rate(1.2K)
Transmit
:
CF CF C0 00 04 12 34 00 61
Return
:
CF CF C1 00 04 12 34 00 61
6
Format error
Reply: FF FF FF
8.2 Register description
Address
Read/
Write
Name
Description
Remark
00H
Read/
Write
ADDH
ADDH
(
Default 0
)
High and low byte of the module
address. Note
:
When the module
address is FFFF, it can be used as the
broadcast and monitor address, that
is the module will not perform
address filtering.
01H
Read/
Write
ADDL
ADDL
(
Default 0
)
02H
Read/
Write
NETID
NETID
(
Default 0
)
Network address, used to distinguish
the network. When communicating
with each other, they should be set to
the same.