background image

11 

 

 

 

 

 

 

 

 

Publication No 2490-08 

 
 

EC DECLARATION OF CONFORMITY 

 

Item 

Content based upon Annex X of ATEX Directive 94/9/EC 

Manufacturer 

Ebsray Pumps Pty Ltd 

 

Address 

628 Pittwater Road Brookvale NSW 2100 Australia 
 

Manufacturer’s Declaration 

We, Ebsray Pumps Pty Ltd declare that the following equipment : 
 

Description of Equipment 

Ebsray V Series Sliding Vane bareshaft Pump ;  

 

Model / Type : 
 

V15 

(all Types) except Liquefied Gases 

 

V20 

(all Types) 

 

V25 

(all Types) except Liquefied Gases 

 

V2000  (all Types) 

 

V3000   (all Types) 

 

V3010   (all Types) 

 

V30 

(all Types) 

 

V40  

(all Types) 

 

V6000  (all Types) 

 

The above Models are positive displacement sliding vane Pumps for liquid 
transfer applications.  These Models / Types must only be applied in systems 
designed for 

that Model/Type’s intended use.  

 
The above Models bear the following marking (where applicable) : 
 

 

      II 2 G c T4  

 

Declaration of compliance 

Is designed and manufactured in compliance with the following applicable 
Directives : 

Applicable Directives 
 evaluated by Manufacturer 
- not checked by Notified 
Body

 

 

First applicable Directive 
 
Individual declaration of 
compliance 
 
 

ATEX Directive 94/9/EC - by application of the following Standards : 
 
 

EN 1127-1 (2007)  

 

EN 13463-1 (2001)  

 

EN 13463-5 (2003) 

Second applicable Directive 

Pressure Equipment Directive (PED) 97/23/EC - but excluded under Article 3.10 
  

Third applicable Directive 

Machinery Directive (MD) 98/37/EC 

– by application of the following Standards : 

 

 

 

EN ISO 12100-1 (2003) 

 

EN ISO 12100-2 (2003) 

 

EN 809 (1998) 

 

Manufacturer’s own 
warning 

Subject to the use for which the product(s) were designed and/or installed in 
accordance with the relevant Standards and Codes 

– all in conjunction with the 

Manufacturer’s own Installation and Operating Instructions and 
recommendations 
 

Final declaration 

We, the undersigned, hereby declare that the product(s) specified conform to the 
listed Directive(s) and Standard(s) 
 

Signatory of person legally 
responsible 
 

Ebsray Pumps Pty Ltd 
 
 
W.A.Ebsary - Managing Director  
   

Place / Date 

 

Brookvale, Australia / 22 April 2008 

 

Symptom 

Possible 

 Problem 

Possible Cause 

Remedy 

Leakage 
from 
Pump

 

Mechanical Seal 
leakage 

Seals incorrectly installed 

Inspect seal assembly, replace if 
necessary and install correctly 

Excessive dry running of pump 

Ensure liquid-state operation of pump 

Seal faces cracked, scratched, pitted 
or dirty 

Inspect and replace seal assembly if 
required 

O-Rings nicked, cut or twisted 

Replace as required 

O-Rings not compatible with 
pumpage 

Replace with O-Rings of a compatible 
material 

Worn or damaged shaft in seal zone 

Replace rotor on shaft assembly 

Misalignment causing excessive 
shaft distortion 

Check and realign as required. 

Excess system pressure 

Check and adjust to requirements 

Casing leakage 

O-Rings failed 

Replace as required 

Fasteners not tight 

Tighten to required torque setting 

Thermal expansion of product when 
locked between valves either side of 
pump 

Remove hydraulic lock potential 

Excessive static pressure 

Eliminate excessive static pressure 

 

APPENDIX A 

– DECLARATION OF CONFORMITY 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for V Series

Page 1: ...Publication 2302 13 EBSRAY PUMPS INSTALLATION OPERATION MAINTENANCE INSTRUCTIONS V SERIES MODELS V2000 V3000 V3010 ROTARY SLIDING VANE PUMPS V3000 V3010 V2000...

Page 2: ...ment s conformity Failure to comply with the instructions and recommendations contained in this Publication may void CE conformity 3 This Publication does NOT depict a Ancillary required equipment rel...

Page 3: ...ipment supplied utilises components other than those manufactured by Ebsray e g electrical equipment switches fittings valves etc reference should be made to the original manufacturer s data before in...

Page 4: ...ve suction resistance 2 5 COUPLING ALIGNMENT To maximise the life of the pump appropriate alignment of the coupled shafts is a fundamental requirement of any coupling installation NOTE Coupling types...

Page 5: ...ing before checking direction of rotation 3 4 OPERATIONAL CHECKS Inspect pump frequently during the first few hours of operation for such conditions as excessive heating of ball bearings vibration or...

Page 6: ...age and straightness Replace the pushrods if they show signs of physical damage wear or distortion e g mushroomed rounded or tapered ends scoring on flanks bending etc 4 Inspect vanes for wear or dama...

Page 7: ...eused as bending the tabs more than once may cause fatigue which could result in failure and or major pump damage Only reassemble with new lockwashers of the correct thickness Refer parts list TO SET...

Page 8: ...7 Dust Cap Inspection End or Shaft Cap Inspection End 1 640 Dowel 2 400 Valve Cover 1 650 Grease Nipple 2 401 Adjusting Screw Bypass Valve 1 651 Grease Pressure Relief 4 409 Valve 1 Adaptor Flange Opt...

Page 9: ...9...

Page 10: ...ve restriction Incorrectly set external Bypass Valve or internal Pressure Relief Valve Valve pressure setting too low Adjust pressure setting but do NOT exceed system design pressure or driver capabil...

Page 11: ...tandards EN ISO 12100 1 2003 EN ISO 12100 2 2003 EN 809 1998 Manufacturer s own warning Subject to the use for which the product s were designed and or installed in accordance with the relevant Standa...

Page 12: ...12 NOTES...