Wireless multi-axis movement detector

 

 

The MD-10 is an indoor wireless multi-axis movement detector that uses triaxial accelerometer technology to sense displacement, tilt 

and vibration caused by for example drilling or sawing. This allows to protect valuable objects such as work of arts, paintings, safes, 
money cassette, etc. Can be used with CPX230NWB alarm control panel. 

Main features 

 

4 sensitivity level 

 

Low power consumption 

 

Supervisory signal every 15 minute during normal working mode 

 

Tamper signal if open cover and detachment from the wall 

 

Battery status control (low-power signal at 2.5 V) 

 

Battery lifetime 2-3 years (lifetime is approximate and depends on the working conditions of the detector) 

 

Max transmission distance 300 m (open air) 

 

Protection against incorrect battery polarity 

Specification 

 

Operation voltage:  

 

 

3 V

 

 

Standby current:  

 

 

<45 uA

 

 

Alarm current:  

 

 

16 mA

 

 

Transmission frequency:   

 

433.92 MHz

 

 

Operation temperature:    

 

-10 ~ 50°C

 

 

Storage temperature:  

 

 

-20 ~ 60°C 

 

Dimensions:   

 

 

85x26x33 mm 

 

Battery: 

  

 

 

lithium, CR123 

Programming mode 

Open detector cover. Set control panel into learning mode and detector into normal mode.. When control panel will be 

waiting for signal from wireless detector push anti-tamper switch. 

WARNING! 

 

Detector installation near the large metal object, high-intensity magnetic fields or high power device will 
cause a working noise. Install in the dry place. 

 

Make sure the place you choose for installation allow free detector-receiver communication. 

 

Fig. 2. Simplified view of the PCB 

 

Fig. 3. DIP switch

 

Slider 1 (LED) – LED indicator: 
ON  

OFF – lower current consumption 

 
Slider 2 (TEST) – Working mode 
ON – Testing mode 

every  detection  in  the  area  controlled  will 
result in the LED flashing 5 times per second 

(without  detection  once  a  second)  and 
sending alarm information to control panel (in 

this mode battery will discharge faster); 

OFF – Normal mode 

it means, that detections (alarms) in the area 

controlled  by  the  sensor  are  sent  to  control 
panel  not  more  than  once  in  3  minutes;  the 

detector should be set in this mode; 

 

Slider 3, 4 (SENS)  - Sensitivity level

 

Tab. 1. DIP switch settings and corresponding sensitivity levels

 

Slider 3 

(SENS1) 

Slider 4 

(SENS2)  Sensitivity level 

ON 

ON 

low 

 

 

      high 

OFF 

ON 

ON 

OFF 

OFF 

OFF 

 

 

 
 

 

EBS Sp. z o. o. 

59 Bronislawa Czecha St. 
04-555 Warsaw, POLAND 
Technical support:  

+48 22 51 88 477 

E-mail:  

 

[email protected] 

Webpage:    

www.ebssmart.com

Fig. 1. Cover disassembly schema 