EN
MD-10_manual_PL_EN_ES_PT_TR_v1.3
MD-10
Wireless multi-axis movement detector
The MD-10 is an indoor wireless multi-axis movement detector that uses triaxial accelerometer technology to sense displacement, tilt
and vibration caused by for example drilling or sawing. This allows to protect valuable objects such as work of arts, paintings, safes,
money cassette, etc. Can be used with CPX230NWB alarm control panel.
Main features
4 sensitivity level
Low power consumption
Supervisory signal every 15 minute during normal working mode
Tamper signal if open cover and detachment from the wall
Battery status control (low-power signal at 2.5 V)
Battery lifetime 2-3 years (lifetime is approximate and depends on the working conditions of the detector)
Max transmission distance 300 m (open air)
Protection against incorrect battery polarity
Specification
Operation voltage:
3 V
Standby current:
<45 uA
Alarm current:
16 mA
Transmission frequency:
433.92 MHz
Operation temperature:
-10 ~ 50°C
Storage temperature:
-20 ~ 60°C
Dimensions:
85x26x33 mm
Battery:
lithium, CR123
Programming mode
Open detector cover. Set control panel into learning mode and detector into normal mode.. When control panel will be
waiting for signal from wireless detector push anti-tamper switch.
WARNING!
Detector installation near the large metal object, high-intensity magnetic fields or high power device will
cause a working noise. Install in the dry place.
Make sure the place you choose for installation allow free detector-receiver communication.
Fig. 2. Simplified view of the PCB
Fig. 3. DIP switch
Slider 1 (LED) – LED indicator:
ON
OFF – lower current consumption
Slider 2 (TEST) – Working mode
ON – Testing mode
every detection in the area controlled will
result in the LED flashing 5 times per second
(without detection once a second) and
sending alarm information to control panel (in
this mode battery will discharge faster);
OFF – Normal mode
it means, that detections (alarms) in the area
controlled by the sensor are sent to control
panel not more than once in 3 minutes; the
detector should be set in this mode;
Slider 3, 4 (SENS) - Sensitivity level
Tab. 1. DIP switch settings and corresponding sensitivity levels
Slider 3
(SENS1)
Slider 4
(SENS2) Sensitivity level
ON
ON
1
low
high
OFF
ON
2
ON
OFF
3
OFF
OFF
4
EBS Sp. z o. o.