LX2NB Manual v.1.3
Page 33 / 57
7.3.4.3.
Time of output activation
Parameter defining amount of time for which the output is to be turned on for the
functions of advanced outputs control.
7.3.4.4.
Event: CLIP
Icoming call from the number defined in option: Inputs/Outputs –>Output 1
(OUT1). The phone number is entered at option: “When icoming call detected from
number” (see item 7.3.3.2.).
7.3.4.5.
Event: Input 5 (RC) and Input 6 (RC)
Virtual RC input (only for LX2NB-5R), which allow you to control the output state.
Possible choices are described in section 7.3.4.1.
7.4.
MONITORING
Thanks to this option you may determine which of available signals generated by
the device shall be transmitted to monitoring station.
NOTE: “Configuration changed” event refer to configuration changes made
by SMS or GPRS commands.
7.4.1.
GPRS On / GPRS Off
In this column you define signals that are to be reported to monitoring station with
GPRS transmission. There is possibility to send information on alarms (input state
change from rest to action status) and on returns of input state from action to rest
(normalization).
To transmit any signal you should only click it (proper square on your right).
Click on [Clear] button to remove all marked signals.
Click on [Invert] button to change markings to contrary.