CPX200NB ALARM CONTROL UNIT – INSTALLER MANUAL
7 / 116
2.
CONTROL UNIT FUNCTIONS
2.1.
FUNCTIONAL CHARACTERISTIC
ZONES
7 wired zones with the NC / NO / EOL-NC / EOL-NO / DEOL-NC / DEOL-NO configuration
possibility
Detection lines – instant, delayed, 24h burglary, arming/disarming, 24h tamper, interior
delay, 24h burglary silent, 24h fire, perimeter, perimeter exit, arming/disarming by state
change
PROGRAMMABLE OUTPUTS
1 monitored alarm output, high-current (max. current 1.1A)
2 monitored alarm outputs, low-current (max. current 50mA)
FEEDING OUTPUTS
1 signalling device output (max. current 350mA)
1 detector output (max. current 350mA)
1 keypad output (max. current 100mA)
PARTITIONS
2 partitions with the possibility to assign any number of zones to each of them
KEYBOARD
cooperation with LED keyboard KP16
ability to connect up to three keypads
TRANSMISSION
Transmission of signals through GPRS/SMS module
Encryption of data transfer using AES standard
Communication with monitoring station using dedicated OSM.Server server that ensures
the reliability of data transfer thanks to a redundancy function
Control of GSM/GPRS connection – automatic restoration of connection with monitoring
station or switching to secondary server
CONFIGURATION
Local, using KP16 keypad or a computer
Remote through GPRS, SMS or CSD
USERS
1 admin code (main)
1 service code
8 user codes
Possibility to restrict the scope of authorization to a few codes only
SYSTEM OPTIONS
Automatic diagnosis of basic system components
Possibility to review faults, alarm memories, event log
System/technical event history – min. 5000 events