CPX200NB ALARM CONTROL UNIT – INSTALLER MANUAL
56 / 116
8.
PROGRAMMABLE PARAMETERS
Parameters available in configuration wizard were divided into groups: Access, Transmission,
Inputs/Outputs, System Options, Users, Monitoring, Restrictions, SMS Notifications, Link
Control, Firmware. Each of the groups will be described in detail further on.
8.1.
ACCESS
8.1.1.
Parameters
8.1.1.1.
Equipment operation mode
Depending on user’s preferences, the equipment can operate in one of 4 modes (to
be selected from a drop list):
GPRS & SMS: GPRS transmission (TCP/IP protocol) in standard and in case of
problems with that connection, automatic switch into SMS mode
SMS: Transmission only in SMS mode without the attempt of establishing a GPRS
connection
GPRS: GPRS transmission (TCP/IP protocol) in standard. In case of any problems
with that connection, no remote connection is possible
No server connection: no transmission with server, remote communication with a
user is possible only via SMS messages