background image

Reassemble the thermometer in reverse order, noting the correct tightening
torque of 0.4 Nm.

To ensure device is fully water-tightness, make sure the seal between lower
and upper housing is seated correctly in the groove.

Use the provided screws and plastic plugs (slightly chamfered surfaces
outward).

Please  avoid  any  electrostatic  discharging  during  the  battery
replacement process.

7

Replacing the battery TFX

Battery operational

You can now see the battery holder (3) with battery (4) on the circuit board (7).
Pull the used battery out of the holder in direction of arrow.

Ensuring fingers are free of grease, insert the new battery into the holder. The
positive sign on the battery must be pointing upwards, i.e. visible.

Short manual

Battery operational
Battery shortly exhausted
Battery needs to be  replaced

The thermometer must be opened to replace the battery.

Remove both plastic plugs (1) with the enclosed sharp implement.

Using  the  enclosed  cross-head  screwdriver,
remove both now visible cross-head screws. (2)

Hold the bottom of the thermometer (6) in one hand
and remove the upper part with the other hand (5).
Pull it out upwards.

The battery symbol on the display indicates that the
battery needs to be replaced.

3

4

2

6

1

5

Reassemble the thermometer in reverse order, noting the correct tightening
torque of 0.4 Nm.

To ensure device is fully water-tightness, make sure the seal between lower
and upper housing is seated correctly in the groove.

Use the provided screws and plastic plugs (slightly chamfered surfaces
outward).

Please  avoid  any  electrostatic  discharging  during  the  battery
replacement process.

7

Replacing the battery TFX

Battery operational

You can now see the battery holder (3) with battery (4) on the circuit board (7).
Pull the used battery out of the holder in direction of arrow.

Ensuring fingers are free of grease, insert the new battery into the holder. The
positive sign on the battery must be pointing upwards, i.e. visible.

Short manual

Battery operational
Battery shortly exhausted
Battery needs to be  replaced

The thermometer must be opened to replace the battery.

Remove both plastic plugs (1) with the enclosed sharp implement.

Using  the  enclosed  cross-head  screwdriver,
remove both now visible cross-head screws. (2)

Hold the bottom of the thermometer (6) in one hand
and remove the upper part with the other hand (5).
Pull it out upwards.

The battery symbol on the display indicates that the
battery needs to be replaced.

3

4

2

6

1

5

Reviews: