MicroLab

Operating Manual –

English

Summary of Contents for CareFusion MicroLab

Page 1: ...1 MicroLab Operating Manual English...

Page 2: ...ting started 10 Calibration Check 15 Customisation 17 Administration Mode 18 Paper Loading 19 External printing 20 PC connection using SPCS 20 Cleaning the Transducer 22 Servicing 23 Consumables suppo...

Page 3: ...orm of volume transducer which measures expired air directly at B T P S Body Temperature and Pressure with Saturated water vapour thus avoiding the inaccuracies of temperature corrections The transduc...

Page 4: ...uch the name of the required region with the stylus stored on the left hand side of the unit and then touch Finish This will set the regional defaults including language if available If this screen is...

Page 5: ...lecting from the list displayed Touch the toolbox icon to adjust volume and brightness Four levels of battery charge are indicated by the segmented battery icon When this icon turns red the battery is...

Page 6: ...d workflow is to enter the patient s details or retrieve them from memory perform the required test and then print and save the results Please ensure that the turbine transducer is plugged in to eithe...

Page 7: ...the help button to obtain further information To add a patient to the database use the on screen keyboard to type a unique patient ID and then touch the enter key You will then be prompted for Last Na...

Page 8: ...H Quanjer et al Eur Respir J 1993 6 Suppl 16p5 40 Once all the patient details are added the patient is added to the database and the main menu is displayed with the patient name displayed at the bot...

Page 9: ...iration When a manoeuvre has been obtained touch Results to view the indices Again to repeat the manoeuvre Reject to delete the manoeuvre or Done to end the test All the active indices are displayed f...

Page 10: ...cted the default graph will be displayed This may be changed by touching the arrows at the top of the screen Flow Volume Volume time or child incentive default displays may be selected using the custo...

Page 11: ...end stop is reached and then immediately empty the syringe completely Try to maintain a flow rate that keeps the trace within the grey bands on the display Press Reject to retry the calibration check...

Page 12: ...ed The calibration error should be less that 3 If a greater error is shown repeat the procedure ensuring that the syringe is emptied and filled in a smooth manner without jerking the handle If an erro...

Page 13: ...metry options allow you to configure the following Relaxed spirometry mode with or without tidal breathing Predicted value sets Predicted area or line display Display default Incentive display type Pr...

Page 14: ...disabling of the Database Management icon will prevent the user from deleting any patient details or test results To enter administration mode turn the unit on whilst holding down the help key The def...

Page 15: ...ce the paper into the compartment as shown and close the cover firmly It is recommended that only CareFusion thermal printer paper Cat No 36 PSA1600 is used with the MicroLab to avoid damage to the th...

Page 16: ...shipped from the factory and should be fully charged on first use Plug the AC adapter into the mains supply and plug the adapter output plug into the power input socket on the right hand side of the...

Page 17: ...ed to a computer that is manufactured in accordance with EN60950 1992 1993 Safety of Information Technology Equipment including Electrical Business Equipment Keep the PC out of reach of the patient at...

Page 18: ...n below 2 Gently pull the transducer away from the housing 3 The transducer may now be immersed in warm soapy water for routine cleaning or immersed in cold disinfecting solutions e g Perasafe for a m...

Page 19: ...y presses hold the on off button down for 10 seconds until the unit switches off and then turn on again Symbols Type B device 0086 In accordance with Directive 93 42 EEC Disposal in compliance with WE...

Page 20: ...Filters 25 per box 36 MGF1100 MicroGard Pulmonary Filters 100 per box 36 SSC5000A PeraSafe Sterilising Powder 81g to make up 5 litres of solution 36 VOL2104 Nose Clips pack of 5 36 SM2125 3 Litre Cal...

Page 21: ...meter Case Studies Specification of the MicroLab General Storage 2000 tests including Flow Volume loops and Volume Time curves Printer Output Compatible Hewlett Packard USB printers Specified models o...

Page 22: ...6 FEV 75 FEV6 FEV1 as a percentage of FEV6 FEV1 FEV6 Maximum Expired Flow at 75 of FVC remaining MEF75 Maximum Expired Flow at 50 of FVC remaining MEF50 Maximum Expired Flow at 25 of FVC remaining MEF...

Page 23: ...Relaxed vital capapcity EVC Inspiratory vital capacity IVC Breathing frequency rate FR Inspiratory time Ti Expiratory time Te Ti as a of total breath timel Ti Ttot Tidal volume as a of Ti TV Ti Tests...

Page 24: ......