Receiver - Wall-Mounted Appliance Module
Ref : RMA
July 2009
page 7
RMA
1.Take off the paddle of the receiver.
2.Press and keep pressed the key PROG till LED lights up green (after
3 seconds).
3.Release PROG key.
4.Press/release minimum 10 times the key PROG, the LED starts
blinking for 5 times then to blink off. You are now in secured mode.
5.Just put on again the paddle (make sure
ebode
log is located on
the bottom right side).
ON
OFF
1.Take off the paddle of the receiver.
2.Press shortly the key PROG, LED blinks quickly in green showing
the receiver is awaiting an order from any transmitter (can be either
RF or PLC mode).
3.Choose and press the choosen key of a remote or transmitter
(RF remote, PLC command/programmer) to automatically learn the
address.
4.Green LED blinks off to acknowledge the order.
5.The unique address is now confirmed.
6.In case of you would like to learn more than one command (RF
remote, PLC command/programmer) just proceed same way from
step 2 up to 4.
7.Once learning is complete, just put the paddle back onto the
receiver.
NOTE : For proper installation, make sure logo ebode shown on the
paddle is positioned on the bottom right side.
To switch from standard to secure
communication protocol
.
The secure mode
ebode
can be enabled in case of safety requested
mode. To do so, ONLY transmitters TPC, EM and IMRF can be in
control of receivers appliance/lighting RMA, shutter RMV and plug
in module RPT.
The
ebode
communication protocol can be associated as a professionnal
security communication, mostly used in alarm systems.
FYI :
- Once powered on, the RMA receiver is in the mode to acknowledge X10
standard controls (To secure communication beteween transmitter and receiver
pls refer to step 4).
- The RMA receiver takes into control any Radio Frequency Order coming
in from any transmitter, then translate and transmit over the home existing
electrical wirings.
L
: stands for input Live 230V - 50 Hz
N
: stands for input Neutral 230V - 50Hz
N
: Neutral