4.4 Connection diagram

Three-phase motor with externally wired TOP
Change of rotation direction by reversing two phases

Δ

Delta connection

L1

blue

L2

black

L3

brown

TW

Thermal overload protector gray (2x)

PE

green/yellow

Item no. 15828-5-9970 · ENU · Change 99214 · Approved 2018-05-15 · Page 10 / 13

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Summary of Contents for W6D630-KN01-01

Page 1: ...zed technical staff Only authorized specialists are permitted to install the device to carry out a test run and to perform work on the electrical installation 1 3 Basic safety rules 1 1 3 Basic safety...

Page 2: ...grill to load Do not place any objects on the guard grill There must be sufficient space around the fan to be able to get past the fan 1 6 Mechanical movement DANGER Rotating device Risk of injury to...

Page 3: ...ng the device in the following ways is prohibited and could be hazardous Operating the device in an unbalanced state e g due to dirt deposits or ice formation Resonant operation operation with severe...

Page 4: ...l dimensions in mm 1 Airflow direction V 2 Cable silicone 6G 0 5 mm 6x crimped ferrules 3 Mounting holes for FlowGrid Item no 15828 5 9970 ENU Change 99214 Approved 2018 05 15 Page 4 13 ebm papst Mulf...

Page 5: ...port struts only in X position as illustrated or rotor on bottom 2 For horizontal shaft installation position the cable exit must be at the bottom right Item no 15828 5 9970 ENU Change 99214 Approved...

Page 6: ...ith PP plastic Fan housing material PP plastic Material guide vanes PP plastic Guard grille material Steel coated with black plastic RAL 9005 Number of blades 5 Airflow direction V Direction of rotati...

Page 7: ...nnections of the motor heating tape and drip pan The terminal box kit to suit the AxiCool fan housing and motor is available from ebm papst under the following item number Motor connection Item no M__...

Page 8: ...ss section equal to or greater than that of the phase conductor We recommend the use of 105 C cables Ensure that the minimum cable cross section is at least AWG 26 0 13 mm Protective earth contact res...

Page 9: ...hen working on the device secure the system machine in which the device is installed so as to prevent it from being switched back on NOTE Lack of motor protection Without motor protection the motor ca...

Page 10: ...ange of rotation direction by reversing two phases Delta connection L1 blue L2 black L3 brown TW Thermal overload protector gray 2x PE green yellow Item no 15828 5 9970 ENU Change 99214 Approved 2018...

Page 11: ...etermined in the course of fan commissioning Either run through the resonant range as quickly as possible with speed control or find another remedy Operation with excessively high vibration levels can...

Page 12: ...tection are fixed criteria The following section contains recommendations for ecological disposal of the product and its components 5 3 1 Country specific legal requirements NOTE Country specific lega...

Page 13: ...mploying the proper procedures for electronic scrap Please contact ebm papst for any other questions on disposal Item no 15828 5 9970 ENU Change 99214 Approved 2018 05 15 Page 13 13 ebm papst Mulfinge...

Reviews: