3.2 Nominal data

Motor

M4E068-DF

Phase

1~

1~

Nominal voltage / VAC

230

230

Frequency / Hz

50

60

Type of data definition

fa

fa

Valid for approval /
standard

CE

CE

Speed / min

-1

1390

1600

Power input / W

120

140

Current draw / A

0.57

0.61

Motor capacitor / µF

4

4

Capacitor voltage / VDB

400

400

Max. back pressure / Pa

90

75

Min. ambient
temperature / °C

-25

-25

Max. ambient
temperature / °C

40

40

Starting current / A

1.4

1.3

ml = max. load · me = max. efficiency · fa = running at free air

cs = customer specs · cu = customer unit

Subject to alterations

3.3 Data according to ErP directive

Installation category

A

Efficiency category

Static

Variable speed drive

No

Specific ratio

*

1.00

*

Specific ratio = 1 + p

fs

/ 100 000 Pa

Actual

Request
2013

Request
2015

Overall efficiency η

es

24.7

24.1

28.1

Efficiency grade N

36.6

36

40

Power input P

e

/ kW

0.13

Air flow q

v

/ m³/h

1950

Pressure increase total p

sf

/ Pa

62

Speed n / min

-1

1345

Data established at point of optimum efficiency

3.4 Technical features

Mass

5.3 kg

Size

330 mm

Surface of rotor

Coated in black

Material of blades

Sheet steel, coated in black

Material of wall ring

Sheet steel, pre-galvanised and coated in
black plastic

Material of guard grille

Steel, phosphated and coated in black
plastic

Number of blades

5

Direction of air flow

"A"

Direction of rotation

Clockwise, seen on rotor

Type of protection

IP 44; Depending on installation and
position as per EN 60034-5

Insulation class

"B"

Humidity class

F1-2

Mounting position

Any

Condensate discharge
holes

Rotor-side

Operation mode

S1

Motor bearing

Ball bearing

Touch current acc.
IEC 60990 (measuring
network Fig. 4, TN
system)

< 0.75 mA

Motor protection

Thermal overload protector (TOP) wired
internally

Cable exit

Axial

Protection class

I (if protective earth is connected by
customer)

Product conforming
to standard

CE

For cyclic speed loads, note that the rotating parts of the device
are designed for maximum one million load cycles. If you have
specific questions, contact ebm-papst for support.

3.5 Mounting data

For depth of screw, see chapter 3.1 Product drawing

;

Secure the mounting screws against accidentally coming loose (e.g.
by using self-locking screws).

You can obtain additional mounting data from the product drawing if
necessary.

3.6 Transport and storage conditions

;

Use the device in accordance with its protection type.

Max. permissible
ambient motor temp.
(transp./ storage)

+ 80 °C

Min. permissible
ambient motor temp.
(transp./storage)

- 40 °C

Item no. 12120-5-9970 · Revision 76115 · Release 2012-01-30 · Page 5 / 9

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

E-mail: [email protected]  

Summary of Contents for W4E330-CP18-31

Page 1: ...and authorised specialist personnel are permitted to transport unpack assemble operate or maintain the device or to use it in any other manner 1 3 Basic safety rules 1 1 3 Basic safety rules Any safe...

Page 2: ...tangled and pulled into the device You could be injured Do not wear any loose clothing or jewellery while working on rotating parts Protect long hair by wearing a cap 1 7 Emission WARNING Depending on...

Page 3: ...ways is particularly prohibited and may cause hazards Operating the device with an imbalance e g caused by dirt deposits or icing Moving air that contains abrasive particles Moving highly corrosive ai...

Page 4: ...s have the unit mm 1 Direction of air flow A 2 Connection line PVC 4G 0 5mm 4x brass lead tips crimped Item no 12120 5 9970 Revision 76115 Release 2012 01 30 Page 4 9 ebm papst Mulfingen GmbH Co KG Ba...

Page 5: ...and coated in black plastic Number of blades 5 Direction of air flow A Direction of rotation Clockwise seen on rotor Type of protection IP 44 Depending on installation and position as per EN 60034 5...

Page 6: ...dry environment Connect the device only to circuits that can be switched off using an all pole disconnecting switch 4 2 1 Prerequisites Check whether the data on the type plate agree with the connect...

Page 7: ...Connection screen U1 blue Z brown U2 black PE green yellow Item no 12120 5 9970 Revision 76115 Release 2012 01 30 Page 7 9 ebm papst Mulfingen GmbH Co KG Bachm hle 2 D 74673 Mulfingen Phone 49 0 7938...

Page 8: ...ock risk of injury Discharge the capacitors before working on the device CAUTION The motor restarts automatically when operating voltage is applied e g after a power failure Danger of injury Keep out...

Page 9: ...damage to blades and housing Visual inspection At least every 6 months Replacement of the device Mounting the connection lines Visual inspection At least every 6 months Fasten Mounting of protective e...