ebm-papst W4E315-DS20-38 Operating Instructions Manual Download Page 8

Operating instructions

W4E315-DS20-38

Translation of the original operating instructions

4.4 Connection screen

L

blue

N

black

PE

green/yellow

TOP

grey

Item no. 14349-5-9970 · Revision 83262 · Release 2014-05-26 · Page 8 / 11

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Summary of Contents for W4E315-DS20-38

Page 1: ...sed technical staff Only authorised specialists are permitted to install the device to carry out a test run and to perform work on the electrical installation 1 3 Basic safety rules 1 1 3 Basic safety...

Page 2: ...ng hair loose items of clothing and jewellery could become entangled and pulled into the device You could be injured Do not wear any loose clothing or jewellery while working on rotating parts Protect...

Page 3: ...particularly prohibited and may cause hazards Operating the device with an imbalance e g caused by dirt deposits or icing Opening the terminal box during operation Moving air that contains abrasive p...

Page 4: ...have the unit mm 1 Direction of air flow A 2 Tightening torque 0 5 0 1 Nm 3 Cable diameter max 7 5 mm tightening torque 1 3 0 2 Nm Item no 14349 5 9970 Revision 83262 Release 2014 05 26 Page 4 11 ebm...

Page 5: ...ition Shaft horizontal or rotor on bottom rotor on top on request Condensate discharge holes Rotor side Operation mode S1 Motor bearing Ball bearing Touch current acc IEC 60990 measuring network Fig 4...

Page 6: ...earth must have a cross section equal to or greater than the outer conductor cross section We recommend the use of 105 C cables Ensure that the minimum cable cross section is at least AWG26 0 13 mm Ea...

Page 7: ...vice Only connect the device to circuits which can be de energised with an all pole disconnection switch When working on the device the system machine in which the device is installed must be secured...

Page 8: ...tructions 4 4 Connection screen L blue N black PE green yellow TOP grey Item no 14349 5 9970 Revision 83262 Release 2014 05 26 Page 8 11 ebm papst Mulfingen GmbH Co KG Bachm hle 2 D 74673 Mulfingen Ph...

Page 9: ...that all screws and screwed cable glands are properly tightened 4 7 Switch on device The device may only be switched on if it has been installed properly and in accordance with its intended use includ...

Page 10: ...tage faulty Check mains supply voltage restore power supply Faulty connection De energise correct connection see connection diagram Thermal overload protector responded Allow motor to cool off locate...

Page 11: ...d seams for crack formation Visual inspection At least every 6 months Replace device Item no 14349 5 9970 Revision 83262 Release 2014 05 26 Page 11 11 ebm papst Mulfingen GmbH Co KG Bachm hle 2 D 7467...

Page 12: ...AQ02 09 R2D140 AB02 14 R2D220 AA24 13 R3G310 AL09 30 R4E180 AS11 09 R4E400 AP15 10 REF100 11 14 S2E250 AL06 12 S4E300 AS72 50 S4E450 AU03 02 9496 2 4039 1 A2D250 AA02 18 A2E300 AP02 01 A4E300 AS72 01...