ebm-papst W3G400-CA22-73 Operating Instructions Manual Download Page 9

Operating instructions

W3G400-CA22-73

Translation of the original operating instructions

4.4 Connection diagram

Drawing preliminary!

Item no. 53349-5-9970 · ENU · Change 202174 · Approved 2019-01-04 · Page 9 / 12

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Summary of Contents for W3G400-CA22-73

Page 1: ...authorized specialists are permitted to install the device to carry out a test run and to perform work on the electrical installation 1 3 Basic safety rules 1 1 3 Basic safety rules The safety hazard...

Page 2: ...by the fan when in operation Never step on the guard grill or subject the guard grill to load Do not place any objects on the guard grill There must be sufficient space around the fan to be able to ge...

Page 3: ...he permitted ambient temperature range see Chapter 3 6 Transport and storage conditions and Chapter 3 2 Nominal data Operating the device with all protective devices Following the operating instructio...

Page 4: ...dimensions in mm 1 Direction of air flow V 2 Cable PVC AWG18 5x crimped ferrules 3 Cable PVC AWG22 3x crimped ferrules Item no 53349 5 9970 ENU Change 202174 Approved 2019 01 04 Page 4 12 ebm papst Mu...

Page 5: ...bination in a standardized measurement setup 3 4 Technical description Weight 9 1 kg Size 400 mm Motor size 84 Rotor surface Painted black Electronics housing material Die cast aluminum Blade material...

Page 6: ...g Strictly avoid shocks Wear safety shoes and cut resistant safety gloves CAUTION The blades of the impeller could be damaged Carefully set down the fan on a soft surface Make sure the blades are not...

Page 7: ...he motor is at a standstill and the line voltage is switched on The values are typically in the range 250 mA At the same time the effective power in this operating state operational readiness is typic...

Page 8: ...U shaped loop Fans installed upright Fig 2 Cable routing for fans installed upright The cables must always be routed downward Item no 53349 5 9970 ENU Change 202174 Approved 2019 01 04 Page 8 12 ebm...

Page 9: ...ting instructions 4 4 Connection diagram Drawing preliminary Item no 53349 5 9970 ENU Change 202174 Approved 2019 01 04 Page 9 12 ebm papst Mulfingen GmbH Co KG Bachm hle 2 D 74673 Mulfingen Phone 49...

Page 10: ...ound connection last 5 INTEGRATED PROTECTIVE FEATURES The integrated protective functions cause the motor to switch off automatically in the event of the faults described in the table Fault Safety fea...

Page 11: ...or sharp edged objects for cleaning If cleaning agents have been used rinse these off with clean water If severe corrosion is visible on load bearing or rotating parts switch off the device immediatel...

Page 12: ...nts could drop off during disassembly This can result in fatal or serious injury and material damage Secure components before unfastening to stop them falling 6 3 3 Component disposal The products are...