ebm-papst W3G350-CN01-32 Operating Instructions Manual Download Page 4

Operating instructions

W3G350-CN01-32

Translation of the original operating instructions

3. TECHNICAL DATA

3.1 Product drawing

All measures have the unit mm.

1

Direction of air flow "V"

2

Connection line PVC 3G AWG20, 3x brass lead tips crimped

3

Connection line PVC 4X AWG22, 4x brass lead tips crimped

Item no. 51541-5-9970 · ENG · Revision 85329 · Release 2015-04-29 · Page 4 / 11

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Summary of Contents for W3G350-CN01-32

Page 1: ...lists are permitted to install the device to carry out a test run and to perform work on the electrical installation 1 3 Basic safety rules 1 1 3 Basic safety rules Any safety hazards stemming from th...

Page 2: ...ectromagnetic interferences after integrating the device in installations on the customer s side Verify that the entire setup is EMC compliant 1 7 Mechanical movement DANGER Rotating device Body parts...

Page 3: ...in place Minding the operating instructions Improper use Using the device in the following ways is particularly prohibited and may cause hazards Operating the device with an imbalance e g caused by d...

Page 4: ...m 1 Direction of air flow V 2 Connection line PVC 3G AWG20 3x brass lead tips crimped 3 Connection line PVC 4X AWG22 4x brass lead tips crimped Item no 51541 5 9970 ENG Revision 85329 Release 2015 04...

Page 5: ...nt configuration 3 4 Technical features Mass 5 2 kg Size 350 mm Material of blades Press fitted sheet steel blank sprayed with PP plastic Material of wall ring Sheet steel galvanised and coated in bla...

Page 6: ...component and features no electrically isolating switch Only connect the fan to circuits that can be switched off with an all pole separating switch When working on the fan you must switch off the in...

Page 7: ...t delay We recommend residual current devices with a trigger threshold of 300 mA and delayed triggering super resistant characteristic K 4 2 4 Locked rotor protection Due to the locked rotor protectio...

Page 8: ...GND Connection for control interface 2 0 10V PWM yellow Control input 0 10 V or PWM electrically isolated 3 10V max 1 1mA red Voltage output 10 V 1 1 mA electrically isolated not short circuit proof I...

Page 9: ...able Malfunctions Description Function of safety feature Rotor position detection error An automatic restart occurs Locked rotor After the blockage is removed the motor restarts automatically 6 MAINTE...

Page 10: ...igorously implemented around the world on the basis of German standards Right from the development stage ecological design technical safety and health protection are fixed criteria The following secti...

Page 11: ...ploying the proper procedures for electronic scrap Please contact ebm papst for any other questions on disposal Item no 51541 5 9970 ENG Revision 85329 Release 2015 04 29 Page 11 11 ebm papst Mulfinge...

Reviews: