3. TECHNICAL DATA

3.1 Product drawing

All dimensions in mm.

1

Direction of air flow "V"

2

Cable PVC 3x AWG20, 3x crimped splices

3

Cable PVC 4xAWG22, 4x crimped splices

Item no. 51501-5-9970 · ENU · Change 202174 · Approved 2019-01-04 · Page 4 / 11

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Summary of Contents for W3G350-CG03-32

Page 1: ...authorized technical staff Only authorized specialists are permitted to install the device to carry out a test run and to perform work on the electrical installation 1 3 Basic safety rules 1 1 3 Basi...

Page 2: ...lectrical or electromagnetic interference after installing the device in customer equipment Verify that the entire setup is EMC compliant 1 7 Mechanical movement DANGER Rotating device Risk of injury...

Page 3: ...ld be hazardous Operating the device in an unbalanced state e g due to dirt deposits or ice formation Resonant operation operation with severe vibration This also includes vibration transmitted to the...

Page 4: ...imensions in mm 1 Direction of air flow V 2 Cable PVC 3x AWG20 3x crimped splices 3 Cable PVC 4xAWG22 4x crimped splices Item no 51501 5 9970 ENU Change 202174 Approved 2019 01 04 Page 4 11 ebm papst...

Page 5: ...CSA C22 2 No 77 CAN CSA E60730 1 With regard to cyclic speed loads note that the rotating parts of the device are designed for a maximum of one million load cycles If you have special questions consul...

Page 6: ...cables Water ingress at the customer end of the cable can damage the device Make sure the end of the cable is connected in a dry environment Only connect the device to circuits that can be switched o...

Page 7: ...nt LRA is equal to or less than the nominal current FLA 4 3 Connecting the cables The device has external leads First connect the PE protective earth Connect the cables according to your application W...

Page 8: ...ve earth 1 GND blue GND connection for control interface 2 0 10V PWM yellow Control input 0 10 V or PWM electrically isolated 3 10 V max 1 1 mA red Voltage output 10 VDC 1 1 mA electrically isolated s...

Page 9: ...nnecting be sure to disconnect the ground connection last 5 INTEGRATED PROTECTIVE FEATURES The integrated protective functions cause the motor to switch off automatically in the event of the faults de...

Page 10: ...n accordance with ISO 14001 and rigorously implemented around the world on the basis of German standards Right from the development stage ecological design technical safety and health protection are f...

Page 11: ...omponents employing the proper procedures for electronic scrap Please contact ebm papst for any other questions on disposal Item no 51501 5 9970 ENU Change 202174 Approved 2019 01 04 Page 11 11 ebm pa...

Reviews: