3.2 Nominal data
Motor
M3G074-CF
Phase
1~
Nominal voltage / VAC
230
Nominal voltage
range / VAC
200 .. 277
Frequency / Hz
50/60
Method of obtaining
data
fa
Speed (rpm) / min
-1
1540
Power consumption / W
150
Current draw / A
1.2
Min. ambient
temperature / °C
-25
Max. ambient
temperature / °C
60
ml = Max. load · me = Max. efficiency · fa = Free air
cs = Customer specification · ce = Customer equipment
Subject to change
3.3 Data according to ErP Directive
Actual
Req. 2015
01 Overall efficiency η
es
/ %
41.6
28.6
02 Measurement category
A
03 Efficiency category
Static
04 Efficiency grade N
53
40
05 Variable speed drive
Yes
06 Year of manufacture
The year of manufacture is specified on the
product's rating label.
07 Manufacturer
ebm-papst Mulfingen GmbH & Co. KG
Amtsgericht (court of registration) Stuttgart
· HRA 590344
D-74673 Mulfingen
08 Type
W3G350-CA58-02
09 Power consumption P
ed
/ kW
0.16
09 Air flow q
v
/ m³/h
2195
09 Pressure increase total p
sf
/
Pa
100
10 Speed (rpm) n / min
-1
1450
11 Specific ratio
*
1.00
12 Recycling/disposal
Information on recycling and disposal is
provided in the operating instructions.
13 Maintenance
Information on installation, operation and
maintenance is provided in the operating
instructions.
14 Additional components
Components used to calculate the energy
efficiency that are not apparent from the
measurement category are detailed in the
CE declaration.
*
Specific ratio = 1 + p
fs
/ 100 000 Pa
Data obtained at optimum efficiency level. The ErP data is determined using a motor-impeller
combination in a standardized measurement setup.
3.4 Technical description
Weight
2.9 kg
Fan size
350 mm
Electronics housing
material
Die-cast aluminum
Impeller material
Sheet steel, painted black
Number of blades
5
Direction of rotation
"A"
Degree of protection
IP44; installation- and position-dependent
as per EN 60034-5
Insulation class
"B"
Moisture (F) /
Environmental (H)
protection class
F3-1
Installation position
Shaft horizontal or rotor on bottom; rotor
on top on request
Mode
S1
Motor bearing
Ball bearing
Technical features
- Output 10 VDC, max. 1.1 mA
- Tach output
- Motor current limitation
- Soft start
- Control input 0-10 VDC / PWM
- Thermal overload protection for
electronics/motor
Touch current
according to IEC
60990 (measuring
circuit Fig. 4, TN
system)
<= 3.5 mA
Motor protection
Thermal overload protector (TOP)
internally connected
with cable
Variable
Protection class
I (with customer connection of protective
earth)
Conformity with
standards
CE
Approval
CSA C22.2 No. 77; UL 2111
With regard to cyclic speed loads, note that the rotating parts of
the device are designed for a maximum of one million load
cycles. If you have special questions, consult ebm-papst for
support.
3.5 Mounting data
For screw clearance, see Chapter 3.1 Product drawing
;
Secure the screws against unintentional loosening (e.g. use self-
locking screws).
Any further mounting data required can be taken from the product drawing.
3.6 Transport and storage conditions
;
Use the device in accordance with its degree of protection.
Max. permitted
ambient temp. for
motor (transport/
storage)
+ 80 °C
Min. permitted
ambient temp. for
motor (transport/
storage)
- 40 °C
Item no. 51238-5-9970 · ENU · Change 89188 · Approved 2016-04-18 · Page 5 / 11