background image

Operating instructions

W3G300-BV24-01

Translation of the original operating instructions

3.2 Nominal data

Motor

M3G084-BF

Nominal voltage / VDC

26

Nominal voltage
range / VDC

16 .. 32

Method of obtaining
data

fa

Speed (rpm) / min

-1

3160

Power consumption / W

205

Current draw / A

7.9

Min. ambient
temperature / °C

-40

Max. ambient
temperature / °C

95/110

Starting current / A

10

ml = Max. load · me = Max. efficiency · fa = Free air

cs = Customer specification · ce = Customer equipment

Subject to change

3.3 Data according to Commission Regulation (EU) 327/
2011

Actual

Req. 2015

01 Overall efficiency η

es

/ %

46.1

29.8

02 Measurement category

A

03 Efficiency category

Static

04 Efficiency grade N

56.3

40

05 Variable speed drive

Yes

06 Year of manufacture

The year of manufacture is specified on the
product's rating label.

07 Manufacturer

ebm-papst Mulfingen GmbH & Co. KG
Amtsgericht (court of registration) Stuttgart
· HRA 590344
D-74673 Mulfingen

08 Type

W3G300-BV24-01

09 Power consumption P

e

/ kW

0.24

09 Air flow q

v

/ m³/h

1805

09 Pressure increase total p

sf

/

Pa

197

10 Speed (rpm) n / min

-1

3040

11 Specific ratio

*

1.00

12 Recycling/disposal

Information on recycling and disposal is
provided in the operating instructions.

13 Maintenance

Information on installation, operation and
maintenance is provided in the operating
instructions.

14 Additional components

Components used to calculate the energy
efficiency that are not apparent from the
measurement category are detailed in the
CE declaration.

*

Specific ratio = 1 + p

fs

/ 100 000 Pa

Data obtained at optimum efficiency level. The ErP data is determined using a motor-impeller

combination in a standardized measurement setup.

3.4 Technical description

Weight

2 kg

Size

300 mm

Motor size

84

Blade material

PA plastic

Fan housing material

PA plastic

Number of blades

7

Airflow direction

V

Balancing grade
according to DIN ISO
1940-1

G 10

Direction of rotation

Clockwise, viewed toward rotor

Degree of protection

Motor IP24 KM, electronics IP6K9K
(mating connector installed)

Insulation class

"B"

Moisture (F) /
Environmental (H)
protection class

H4

Ambient temperature
note

Over +95 °C with power derating

Installation position

Any

Condensation
drainage holes

None, open rotor

Mode

S1

Motor bearing

Ball bearing; (sealed)

Life expectancy

40,000 h (typical)

Technical features

- Lowering input
- Fault output (high-side switch max. 30
mA)
- INVLIN (inverse linear control input)
- Power limiter
- Load dump (58 V)
- Motor current limitation
- Soft start
- Control input 0-10 VDC/PWM
- Temperature derating
- Overvoltage detection
- Thermal overload protection for
electronics
- Undervoltage detection
- Reverse polarity protection

Electrical hookup

Connector with cable; Standby current
less than 500 µA

Motor protection

Reverse polarity and locked-rotor
protection

with cable

Lateral

Approval

EAC; E1

Comment

Type approval number - 036433

With regard to cyclic speed loads, note that the rotating parts of
the device are designed for a maximum of one million load
cycles. If you have special questions, consult ebm-papst for
support.

;

Use the device in accordance with its degree of protection.

Item no. 51854-5-9970 · ENU · Change 204653 · Approved 2019-06-21 · Page 5 / 11

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Summary of Contents for W3G300-BV24-01

Page 1: ...y authorized specialists are permitted to install the device to carry out a test run and to perform work on the electrical installation 1 3 Basic safety rules 1 1 3 Basic safety rules The safety hazards associated with the device must be assessed again following installation in the final product The locally applicable industrial safety regulations are always to be observed when working on the devi...

Page 2: ... or electromagnetic interference after installing the device in customer equipment Verify that the entire setup is EMC compliant 1 7 Mechanical movement DANGER Rotating device Risk of injury to body parts coming into contact with the rotor or the impeller Secure the device against accidental contact Before working on the system machine wait until all parts have come to a standstill WARNING Rotatin...

Page 3: ...e hazardous Operating the device in an unbalanced state e g due to dirt deposits or ice formation Resonant operation operation with severe vibration This also includes vibration transmitted to the fan from the customer installation Operation in medical equipment with a life sustaining or life support function Conveying solids in the flow medium Painting the device Connections e g screws coming loo...

Page 4: ...x seal TE 828904 1 1 1 UB 1 2 GND 1 3 PWM LIN 1 4 INVLIN 1 5 ABSENK 1 6 Diagnostic output Accessory part Cable 460 mm with mating connector part no 02002 4 1021 not included in scope of delivery 6 pole mating connector TE 1 963212 1 4x receptacle TE 929939 1 2x receptacle TE 929937 1 2 Airflow direction V Item no 51854 5 9970 ENU Change 204653 Approved 2019 06 21 Page 4 11 ebm papst Mulfingen GmbH...

Page 5: ...he ErP data is determined using a motor impeller combination in a standardized measurement setup 3 4 Technical description Weight 2 kg Size 300 mm Motor size 84 Blade material PA plastic Fan housing material PA plastic Number of blades 7 Airflow direction V Balancing grade according to DIN ISO 1940 1 G 10 Direction of rotation Clockwise viewed toward rotor Degree of protection Motor IP24 KM electr...

Page 6: ...damaged Carefully set down the fan on a soft surface Make sure the blades are not subjected to load Following installation make sure the impeller moves easily and that the blades of the impeller are not deformed or bent and do not catch at any point NOTE Damage to the device from vibration Bearing damage shorter service life The fan must not be subjected to force or excessive vibration from sectio...

Page 7: ...105 C cables Ensure that the minimum cable cross section is at least AWG 26 0 13 mm 4 3 Plug connection 4 3 1 Preparing cables for connection The cables including the customer interface are subject to the specifications for internal wiring Ensure conformity with applicable standards and check the degree of protection in the final product after installing the ebm papst device Connect the cables to ...

Page 8: ...y 26 VDC 2 GND Power supply GND reference ground 3 PWMLIN Analog voltage control input 0 10 V or PWM 4 INVLIN Control input inverse linear 5 ABSENK Lowering input 6 DU Diagnostic output Item no 51854 5 9970 ENU Change 204653 Approved 2019 06 21 Page 8 11 ebm papst Mulfingen GmbH Co KG Bachmühle 2 D 74673 Mulfingen Phone 49 0 7938 81 0 Fax 49 0 7938 81 110 info1 de ebmpapst com www ebmpapst com ...

Page 9: ... not switch the motor e g in cyclic operation on and off via power supply Disconnect the device from the power supply 5 MAINTENANCE MALFUNCTIONS POSSIBLE CAUSES AND REMEDIES Do not perform any repairs on your device Send the device to ebm papst for repair or replacement WARNING Live terminals and connections even with device switched off Electric shock Wait five minutes after disconnecting the vol...

Page 10: ...papst environmental protection and resource preservation are top priority corporate goals ebm papst operates an environmental management system which is certified in accordance with ISO 14001 and rigorously implemented around the world on the basis of German standards Right from the development stage ecological design technical safety and health protection are fixed criteria The following section ...

Page 11: ...mploying the proper procedures for electronic scrap Please contact ebm papst for any other questions on disposal Item no 51854 5 9970 ENU Change 204653 Approved 2019 06 21 Page 11 11 ebm papst Mulfingen GmbH Co KG Bachmühle 2 D 74673 Mulfingen Phone 49 0 7938 81 0 Fax 49 0 7938 81 110 info1 de ebmpapst com www ebmpapst com ...

Reviews: