background image

Operating instructions

W2S130-AA19-38

Translation of the original operating instructions

3.2 Nominal data

Motor

M2S052-CA

Phase

2~

2~

Nominal voltage / VAC

400

400

Frequency / Hz

50

60

Method of obtaining
data

fa

fa

Valid for approval/
standard

CE

CE

Speed (rpm) / min

-1

2800

3200

Power consumption / W

41

38

Current draw / A

0.16

0.13

Max. back pressure / Pa

80

120

Min. ambient
temperature / °C

-25

-25

Max. ambient
temperature / °C

50

70

Starting current / A

0.25

0.21

ml = Max. load · me = Max. efficiency · fa = Free air

cs = Customer specification · ce = Customer equipment

Subject to change

3.3 Technical description

Weight

1.1 kg

Size

130 mm

Motor size

52

Rotor surface

Painted black

Blade material

Sheet steel, painted black

Fan housing material

Die-cast aluminum, painted black

Number of blades

7

Airflow direction

V

Direction of rotation

Counterclockwise, viewed toward rotor

Degree of protection

IP20

Insulation class

"B"

Moisture (F) /
Environmental (H)
protection class

H0+

Installation position

Any

Condensation
drainage holes

None, open rotor

Mode

S1

Motor bearing

Ball bearing

Touch current
according to IEC
60990 (measuring
circuit Fig. 4, TN
system)

< 0.75 mA

Motor protection

Thermal overload protector (TOP)
internally connected

Protection class

I (if protective earth is connected by
customer to the housing's connection point)

Conformity with
standards

EN 60335-1; CE

Approval

EAC

With regard to cyclic speed loads, note that the rotating parts of
the device are designed for a maximum of one million load
cycles. If you have special questions, consult ebm-papst for
support.

;

Use the device in accordance with its degree of protection.

Information on surface quality

The surfaces of the products conform to the generally applicable industrial
standard. The surface quality may change during the production period.
This has no effect on strength, dimensional stability and dimensional
accuracy.
The color pigments in the paints used perceptibly react to UV light over
the course of time. This does not however in any way affect the
technical properties of the products. The product is to be protected against
UV radiation to prevent the formation of patches and fading. Changes in
color are not a reason for complaint and are not covered by the warranty.

3.4 Mounting data

For screw clearance, see Chapter 3.1 Product drawing

;

Secure the screws against unintentional loosening (e.g. use self-
locking screws).

Strength class of
screws

8.8

Any further mounting data required can be taken from the product
drawing or Section Chapter 4.1 Mechanical connection.

3.5 Transport and storage conditions

Max. permitted
ambient temp. for
motor (transport/
storage)

+ 80 °C

Min. permitted
ambient temp. for
motor (transport/
storage)

- 40 °C

Item no. 10639-5-9970 · ENU · Change 207628 · Approved 2019-10-24 · Page 5 / 11

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Summary of Contents for W2S130-AA19-38

Page 1: ...and otherwise used by suitably qualified trained and authorized technical staff Only authorized specialists are permitted to install the device to carry out a test run and to perform work on the elect...

Page 2: ...ndstill WARNING Rotating device Long hair and dangling items of clothing jewelry and the like can become entangled and be pulled into the device Injuries can result Do not wear any loose fitting or da...

Page 3: ...ing the device in an unbalanced state e g due to dirt deposits or ice formation Resonant operation operation with severe vibration This also includes vibration transmitted to the fan from the customer...

Page 4: ...dimensions in mm 1 Airflow direction V 2 Cable silicone 2x 0 5 mm 2x splice 3 M4 screw for fastening ground connector Item no 10639 5 9970 ENU Change 207628 Approved 2019 10 24 Page 4 11 ebm papst Mu...

Page 5: ...EAC With regard to cyclic speed loads note that the rotating parts of the device are designed for a maximum of one million load cycles If you have special questions consult ebm papst for support Use...

Page 6: ...tched off with an all pole disconnection switch 4 2 1 Requirements Check whether the information on the nameplate matches the connection data Before connecting the device make sure the power supply ma...

Page 7: ...external leads Connect the cables according to your application When doing so observe Chapter 4 4 Connection diagram Item no 10639 5 9970 ENU Change 207628 Approved 2019 10 24 Page 7 11 ebm papst Mul...

Page 8: ...ons 4 4 Connection diagram L1 blue L2 brown TOP Thermal overload protector Item no 10639 5 9970 ENU Change 207628 Approved 2019 10 24 Page 8 11 ebm papst Mulfingen GmbH Co KG Bachm hle 2 D 74673 Mulfi...

Page 9: ...ain switch 5 MAINTENANCE MALFUNCTIONS POSSIBLE CAUSES AND REMEDIES Do not perform any repairs on your device Send the device to ebm papst for repair or replacement WARNING Live terminals and connectio...

Page 10: ...Abnormal bearing noise acoustic At least every 6 months Replace device 5 3 Disposal For ebm papst environmental protection and resource preservation are top priority corporate goals ebm papst operate...

Page 11: ...omponents employing the proper procedures for electronic scrap Please contact ebm papst for any other questions on disposal Item no 10639 5 9970 ENU Change 207628 Approved 2019 10 24 Page 11 11 ebm pa...