Operating instructions

W2E200-HK38-01

Translation of the original operating instructions

Heating-up of the motor when using a variable frequency drive must be
checked by the customer following installation in the end device.

4.3 Connection via terminal strip

4.3.1 Connecting wires to terminals

WARNING
Live terminals and connections even with device
switched off

Electric shock
→ Wait five minutes after disconnecting the voltage at all poles

before opening the device.

;

Insert the wires into the terminals, see
Chapter 4.4 Connection diagram.

Item no. 10760-5-9970 · ENU · Change 203512 · Approved 2019-04-29 · Page 7 / 11

·

·

·

·

·

·

Summary of Contents for W2E200-HK38-01

Page 1: ...otherwise used by suitably qualified trained and authorized technical staff Only authorized specialists are permitted to install the device to carry out a test run and to perform work on the electrica...

Page 2: ...echanical movement DANGER Rotating device Risk of injury to body parts coming into contact with the rotor or the impeller Secure the device against accidental contact Before working on the system mach...

Page 3: ...evice in the following ways is prohibited and could be hazardous Operating the device in an unbalanced state e g due to dirt deposits or ice formation Resonant operation operation with severe vibratio...

Page 4: ...01 Translation of the original operating instructions 3 TECHNICAL DATA 3 1 Product drawing All dimensions in mm 1 Direction of air flow V 2 For self tapping M5 screws Item no 10760 5 9970 ENU Change 2...

Page 5: ...with customer connection of protective earth Motor capacitor according to EN 60252 1 in safety protection class S0 Conformity with standards EN 60335 1 CE Approval CCC EAC UL 1004 3 CSA C22 2 No 113 V...

Page 6: ...ched back on NOTE Water ingress into wires or cables Water ingress at the customer end of the cable can damage the device Make sure the end of the cable is connected in a dry environment Only connect...

Page 7: ...on in the end device 4 3 Connection via terminal strip 4 3 1 Connecting wires to terminals WARNING Live terminals and connections even with device switched off Electric shock Wait five minutes after d...

Page 8: ...ing instructions W2E200 HK38 01 Translation of the original operating instructions 4 4 Connection diagram PE green yellow N black L blue Item no 10760 5 9970 ENU Change 203512 Approved 2019 04 29 Page...

Page 9: ...MALFUNCTIONS POSSIBLE CAUSES AND REMEDIES Do not perform any repairs on your device Send the device to ebm papst for repair or replacement WARNING Live terminals and connections even with device switc...

Page 10: ...e intervals to the level of dust exposure 5 2 Safety inspection What to check How to check How often What action Contact protection cover for intactness or damage Visual inspection At least every 6 mo...

Page 11: ...scrap e g circuit boards Only ferrite magnets and not rare earth magnets are used in external rotor motors from Ferrite magnets can be disposed of in the same way as normal iron and steel Electrical...

Reviews: