3.2 Nominal data
Motor
M2E068-BF
Phase
1~
1~
1~
Nominal voltage / VAC
230
230
230
Frequency / Hz
50
60
60
Method of obtaining
data
fa
fa
fa
Valid for approval/
standard
CE
CE
UL 2111
Speed / min
-1
2550
2800
2800
Power consumption / W
64
80
85
Current draw / A
0.29
0.35
0.36
Capacitor / µF
1.5
1.5
1.5
Capacitor voltage / VDB
450
450
450
Max. back pressure / Pa
100
120
120
Min. ambient
temperature / °C
-25
-25
-25
Max. ambient
temperature / °C
60
65
65
Starting current / A
0.55
0.54
0.54
ml = Max. load · me = Max. efficiency · fa = Free air
cs = Customer specification · ce = Customer equipment
Subject to change
3.3 Technical description
Weight
2.1 kg
Fan size
200 mm
Rotor surface
Painted black
Blade material
Sheet steel, painted black
Fan housing material
Die-cast aluminum
Number of blades
9
Airflow direction
"V"
Direction of rotation
Counterclockwise, viewed toward rotor
Degree of protection
IP44; installation- and position-dependent
Insulation class
"B"
Moisture (F) /
Environmental (H)
protection class
H0 - dry environment
Installation position
Any
Condensation
drainage holes
None
Mode
S1
Motor bearing
Ball bearing
Touch current
according to IEC
60990 (measuring
circuit Fig. 4, TN
system)
< 0.75 mA
Electrical hookup
Via terminal strip, capacitor connected
Motor protection
Thermal overload protector (TOP)
internally connected
with cable
Variable
Protection class
I (with customer connection of protective
earth)
Motor capacitor
according to EN 60252-
1 in safety protection
class
P0/S0
Conformity with
standards
CE
Approval
CSA C22.2 No. 113; EAC; UL 507;
VDE; CCC
With regard to cyclic speed loads, note that the rotating parts of
the device are designed for a maximum of one million load
cycles. If you have special questions, consult ebm-papst for
support.
3.4 Mounting data
For screw clearance, see Chapter 3.1 Product drawing
;
Secure the screws against unintentional loosening (e.g. use self-
locking screws).
Strength class of
screws
8.8
Any further mounting data required can be taken from the product drawing.
3.5 Transport and storage conditions
;
Use the device in accordance with its degree of protection.
Max. permitted
ambient temp. for
motor (transport/
storage)
+ 80 °C
Min. permitted
ambient temp. for
motor (transport/
storage)
- 40 °C
Item no. 10785-5-9970 · ENU · Change 89188 · Approved 2016-04-18 · Page 5 / 9