ebm-papst W2E142-BB01-21 Operating Instructions Manual Download Page 7

Operating instructions

W2E142-BB01-21

Translation of the original operating instructions

4.3.1 Motor protection

WARNING
Device has no overheating protection

The device is supplied without any automatic overheating
protection. The device can become hot and catch fire.
→ For the version without thermal overload protector, also

install a suitable motor protection switch.

Item no. 15984-5-9970 · ENU · Change 264559 · Approved 2022-07-27 · Page 7 / 11

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Summary of Contents for W2E142-BB01-21

Page 1: ...ansported unpacked installed operated maintained and otherwise used by suitably qualified trained and authorized technical staff Only authorized specialists are permitted to install the device to carr...

Page 2: ...dy parts coming into contact with the rotor or the impeller Secure the device against accidental contact Before working on the system machine wait until all parts have come to a standstill WARNING Rot...

Page 3: ...ing the device in an unbalanced state e g due to dirt deposits or ice formation Resonant operation operation with severe vibration This also includes vibration transmitted to the fan from the customer...

Page 4: ...untinned 3 M4 screw for fastening ground connector Accessory part included separately Housing cover insulation circuit board assembled Oval head screw 2x tightening torque 0 9 0 1 Nm Item no 15984 5...

Page 5: ...rotection class S0 Conformity with standards EN 60335 1 motor does not have factory installed overheating protection CE Use the device in accordance with its degree of protection Information on surfac...

Page 6: ...es designed for the current level indicated on the nameplate For determining the cross section note the sizing criteria according to EN 61800 5 1 The protective earth must have a cross section equal t...

Page 7: ...any automatic overheating protection The device can become hot and catch fire For the version without thermal overload protector also install a suitable motor protection switch Item no 15984 5 9970 EN...

Page 8: ...g instructions 4 4 Connection diagram U1 blue Z brown U2 black Item no 15984 5 9970 ENU Change 264559 Approved 2022 07 27 Page 8 11 ebm papst Mulfingen GmbH Co KG Bachm hle 2 D 74673 Mulfingen Phone 4...

Page 9: ...sconnect the ground connection last 5 MAINTENANCE MALFUNCTIONS POSSIBLE CAUSES AND REMEDIES Do not perform any repairs on your device Send the device to ebm papst for repair or replacement WARNING Liv...

Page 10: ...Abnormal bearing noise acoustic At least every 6 months Replace device 5 3 Disposal For ebm papst environmental protection and resource preservation are top priority corporate goals ebm papst operate...

Page 11: ...omponents employing the proper procedures for electronic scrap Please contact ebm papst for any other questions on disposal Item no 15984 5 9970 ENU Change 264559 Approved 2022 07 27 Page 11 11 ebm pa...