ebm-papst W1G200-EF01-01 Operating Instructions Manual Download Page 4

Operating instructions

W1G200-EF01-01

Translation of the original operating instructions

3. TECHNICAL DATA

3.1 Product drawing

All dimensions in mm.

1

Direction of air flow "V"

2

Cable AWG20
4x splice

Item no. 51715-5-9970 · ENU · Change 204653 · Approved 2019-06-14 · Page 4 / 10

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Summary of Contents for W1G200-EF01-01

Page 1: ...fied trained and authorized technical staff Only authorized specialists are permitted to install the device to carry out a test run and to perform work on the electrical installation 1 3 Basic safety...

Page 2: ...parts coming into contact with the rotor or the impeller Secure the device against accidental contact Before working on the system machine wait until all parts have come to a standstill WARNING Rotat...

Page 3: ...an unbalanced state e g due to dirt deposits or ice formation Resonant operation operation with severe vibration This also includes vibration transmitted to the fan from the customer installation Ope...

Page 4: ...A 3 1 Product drawing All dimensions in mm 1 Direction of air flow V 2 Cable AWG20 4x splice Item no 51715 5 9970 ENU Change 204653 Approved 2019 06 14 Page 4 10 ebm papst Mulfingen GmbH Co KG Bachm h...

Page 5: ...EN 60335 1 EN 60335 2 24 EN 60335 2 80 EN 60335 2 89 Approval VDE CSA C22 2 No 77 EAC UL 1004 3 With regard to cyclic speed loads note that the rotating parts of the device are designed for a maximum...

Page 6: ...the fan secure the system machine in which the fan is installed so as to prevent it from being switched back on NOTE Water ingress into wires or cables Water ingress at the customer end of the cable c...

Page 7: ...ly 24 VDC maximum ripple 3 5 2 GND blue Reference ground 3 Tach white Tach output 1 pulse per revolution Isink max 10 mA open collector 4 PWM 0 10 VDC yellow Control input PWM or 0 10 V RE 100k Item n...

Page 8: ...power supply Disconnect the device from the power supply 5 MAINTENANCE MALFUNCTIONS POSSIBLE CAUSES AND REMEDIES Do not perform any repairs on your device Send the device to ebm papst for repair or r...

Page 9: ...ction cover for intactness or damage Visual inspection At least every 6 months Repair or replacement of device Device for damage to blades and housing Visual inspection At least every 6 months Replace...

Page 10: ...insulating materials on the product in cables and wires are made of similar materials and are therefore to be treated in the same manner The materials concerned are as follows Miscellaneous insulator...

Reviews: