ebm-papst W1G200-EC95-38 Operating Instructions Manual Download Page 4

Operating instructions

W1G200-EC95-38

Translation of the original operating instructions

3. TECHNICAL DATA

3.1 Product drawing

All dimensions in mm.

1

Direction of air flow "V"

2

Pin S, speed selection (flat plug 2.8 x 0.5)

3

Pin L1, phase (flat plug 2.8 x 0.5)

4

Pin N, neutral conductor (flat plug 2.8 x 0.5)

Item no. 53980-5-9970 · ENU · Change 98948 · Approved 2018-04-27 · Page 4 / 11

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Summary of Contents for W1G200-EC95-38

Page 1: ...d authorized technical staff Only authorized specialists are permitted to install the device to carry out a test run and to perform work on the electrical installation 1 3 Basic safety rules 1 1 3 Bas...

Page 2: ...magnetic interference after installing the device in customer equipment Verify that the entire setup is EMC compliant 1 7 Mechanical movement DANGER Rotating device Risk of injury to body parts coming...

Page 3: ...ons Improper use In particular operating the device in the following ways is prohibited and could be hazardous Operating the device in an unbalanced state e g due to dirt deposits or ice formation Res...

Page 4: ...tion of air flow V 2 Pin S speed selection flat plug 2 8 x 0 5 3 Pin L1 phase flat plug 2 8 x 0 5 4 Pin N neutral conductor flat plug 2 8 x 0 5 Item no 53980 5 9970 ENU Change 98948 Approved 2018 04 2...

Page 5: ...a maximum of one million load cycles If you have special questions consult ebm papst for support Use the device in accordance with its degree of protection Information on surface quality The surfaces...

Page 6: ...ngress at the customer end of the cable can damage the device Make sure the end of the cable is connected in a dry environment Only connect the device to circuits that can be switched off with an all...

Page 7: ...he cables must always be routed downward NOTE Cable routing is to be performed accordingly if use is made of the ESM plug in module to connect the fan Item no 53980 5 9970 ENU Change 98948 Approved 20...

Page 8: ...ting instructions 4 5 Connection diagram Drawing preliminary Item no 53980 5 9970 ENU Change 98948 Approved 2018 04 27 Page 8 11 ebm papst Mulfingen GmbH Co KG Bachm hle 2 D 74673 Mulfingen Phone 49 0...

Page 9: ...in switch 5 INTEGRATED PROTECTIVE FEATURES The integrated protective functions cause the motor to switch off automatically in the event of the faults described in the table Fault Safety feature descri...

Page 10: ...of German standards Right from the development stage ecological design technical safety and health protection are fixed criteria The following section contains recommendations for ecological disposal...

Page 11: ...mploying the proper procedures for electronic scrap Please contact ebm papst for any other questions on disposal Item no 53980 5 9970 ENU Change 98948 Approved 2018 04 27 Page 11 11 ebm papst Mulfinge...