Operating instructions
S6E450-AM13-50
Translation of the original operating instructions
3.2 Nominal data
Motor
M6E074-EI
Phase
1~
1~
Nominal voltage / VAC
230
230
Frequency / Hz
50
60
Method of obtaining
data
ml
ml
Valid for approval/
standard
CE
CE
Speed / min
-1
750
700
Power consumption / W
125
150
Current draw / A
0.56
0.66
Capacitor / µF
3
3
Capacitor voltage / VDB
400
400
Capacitor standard
P0 (CE)
P0 (CE)
Max. back pressure / Pa
40
38
Min. ambient
temperature / °C
-25
-25
Max. ambient
temperature / °C
70
50
Starting current / A
0.68
0.68
Max. safe operating
speed / min
-1
1500
@ 70 °C
1500
@ 70 °C
ml = Max. load · me = Max. efficiency · fa = Free air
cs = Customer specification · ce = Customer equipment
Subject to change
3.3 Technical description
Weight
6.1 kg
Fan size
450 mm
Rotor surface
Painted black
Terminal box material
PC/ABS plastic
Blade material
Press-fitted sheet steel blank, sprayed
with PP plastic
Guard grille material
Steel, coated with black plastic (RAL
9005)
Number of blades
5
Airflow direction
"V"
Direction of rotation
Counterclockwise, viewed toward rotor
Degree of protection
IP44; installation- and position-dependent
as per EN 60034-5
Insulation class
"F"
Moisture (F) /
Environmental (H)
protection class
F1-2
Installation position
Shaft horizontal or rotor on bottom; rotor
on top on request
Condensation
drainage holes
On rotor side
Mode
S1
Motor bearing
Ball bearing
Touch current
according to IEC
60990 (measuring
circuit Fig. 4, TN
system)
< 0.75 mA
Electrical hookup
Via terminal box, capacitor integrated and
connected
Motor protection
Thermal overload protector (TOP)
internally connected
with cable
Variable
Protection class
I (with customer connection of protective
earth)
Motor capacitor
according to EN 60252-
1 in safety protection
class
P0/S0
Conformity with
standards
EN 60335-1; CE
Approval
EAC
With regard to cyclic speed loads, note that the rotating parts of
the device are designed for a maximum of one million load
cycles. If you have special questions, consult ebm-papst for
support.
3.4 Mounting data
;
Secure the screws against unintentional loosening (e.g. use self-
locking screws).
Strength class of
screws
8.8
Any further mounting data required can be taken from the product drawing.
3.5 Transport and storage conditions
;
Use the device in accordance with its degree of protection.
Max. permitted
ambient temp. for
motor (transport/
storage)
+ 80 °C
Min. permitted
ambient temp. for
motor (transport/
storage)
- 40 °C
Item no. 14569-5-9970 · ENU · Change 85321 · Approved 2015-12-09 · Page 5 / 10