3. TECHNICAL DATA

3.1 Product drawing

All dimensions in mm.

1

Direction of air flow "A"

3

Tightening torque 0.7 Nm

4

Shown without terminal box cover

5

Cable diameter max. 7.5 mm; tightening torque 1.3 Nm

Item no. 10402-5-9970 · ENU · Change 88948 · Approved 2017-01-17 · Page 4 / 11

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Summary of Contents for S4E400-BP02-36

Page 1: ...wise used by suitably qualified trained and authorized technical staff Only authorized specialists are permitted to install the device to carry out a test run and to perform work on the electrical ins...

Page 2: ...ovement DANGER Rotating device Risk of injury to body parts coming into contact with the rotor or the impeller Secure the device against accidental contact Before working on the system machine wait un...

Page 3: ...device in the following ways is prohibited and could be hazardous Operating the device in an unbalanced state e g due to dirt deposits or ice formation Resonant operation operation with severe vibrat...

Page 4: ...Direction of air flow A 3 Tightening torque 0 7 Nm 4 Shown without terminal box cover 5 Cable diameter max 7 5 mm tightening torque 1 3 Nm Item no 10402 5 9970 ENU Change 88948 Approved 2017 01 17 Pag...

Page 5: ...mm Terminal box material ABS plastic black Blade material Sheet steel painted black Guard grille material Steel phosphated and coated with black plastic Number of blades 5 Airflow direction A Directi...

Page 6: ...Faulty insulation Risk of fatal injury from electric shock Use only cables that meet the specified installation regulations for voltage current insulation material capacity etc Route cables so that t...

Page 7: ...he cable gland is sealed and there is no strain on the connections For tightening torques see Chapter 3 1 Product drawing NOTE Tightness and strain relief are dependent on the cable used This must be...

Page 8: ...tions 4 4 Connection diagram L U1 blue Z brown N U2 black PE green yellow Item no 10402 5 9970 ENU Change 88948 Approved 2017 01 17 Page 8 11 ebm papst Mulfingen GmbH Co KG Bachm hle 2 D 74673 Mulfing...

Page 9: ...se for instance from inexpert handling transportation damage and resultant imbalance or be caused by component or structural resonance Speed ranges with excessively high vibration levels and possibly...

Page 10: ...ld on the basis of German standards Right from the development stage ecological design technical safety and health protection are fixed criteria The following section contains recommendations for ecol...

Page 11: ...mploying the proper procedures for electronic scrap Please contact ebm papst for any other questions on disposal Item no 10402 5 9970 ENU Change 88948 Approved 2017 01 17 Page 11 11 ebm papst Mulfinge...

Reviews: