3.2 Nominal data

Motor

M4E068-CF

Phase

1~

1~

Nominal voltage / VAC

230

230

Frequency / Hz

50

60

Method of obtaining
data

ml

ml

Valid for approval/
standard

CE

CE

Speed (rpm) / min

-1

1320

1500

Power consumption / W

72

90

Current draw / A

0.32

0.4

Capacitor / µF

2

2

Capacitor voltage / VDB

400

400

Capacitor standard

P0 (CE)

P0 (CE)

Max. back pressure / Pa

60

60

Min. ambient
temperature / °C

-40

-40

Max. ambient
temperature / °C

50

50

Starting current / A

0.6

0.57

ml = Max. load · me = Max. efficiency · fa = Free air

cs = Customer specification · ce = Customer equipment

Subject to change

3.3 Technical description

Weight

2.9 kg

Fan size

300 mm

Rotor surface

Painted black

Terminal box material

ABS plastic, black

Impeller material

PP plastic

Guard grille material

Steel, phosphated and coated with black
plastic

Number of blades

5

Airflow direction

"V"

Direction of rotation

Counterclockwise, viewed toward rotor

Degree of protection

IP44; installation- and position-dependent

Insulation class

"B"

Moisture (F) /
Environmental (H)
protection class

F2-2

Installation position

Any

Condensation
drainage holes

None

Mode

S1

Motor bearing

Ball bearing with low-temperature lubricant

Touch current
according to IEC
60990 (measuring
circuit Fig. 4, TN
system)

< 0.75 mA

Electrical hookup

Via terminal box, capacitor integrated and
connected

Motor protection

Thermal overload protector (TOP)
internally connected

with cable

Axial

Protection class

I (with customer connection of protective
earth)

Motor capacitor
according to EN 60252-
1 in safety protection
class

P0/S0

Conformity with
standards

EN 60335-1; CE

Approval

EAC

With regard to cyclic speed loads, note that the rotating parts of
the device are designed for a maximum of one million load
cycles. If you have special questions, consult ebm-papst for
support.

3.4 Mounting data

;

Secure the screws against unintentional loosening (e.g. use self-
locking screws).

Strength class of
screws

8.8

Any further mounting data required can be taken from the product drawing.

3.5 Transport and storage conditions

;

Use the device in accordance with its degree of protection.

Max. permitted
ambient temp. for
motor (transport/
storage)

+ 70 °C

Min. permitted
ambient temp. for
motor (transport/
storage)

- 40 °C

Item no. 12325-5-9970 · ENU · Change 88936 · Approved 2016-04-18 · Page 5 / 10

Summary of Contents for S4E300-AS72-57

Page 1: ...cations 1 1 2 Staff qualifications The device may only be transported unpacked installed operated maintained and otherwise used by suitably qualified trained and authorized technical staff Only authorized specialists are permitted to install the device to carry out a test run and to perform work on the electrical installation 1 3 Basic safety rules 1 1 3 Basic safety rules The safety hazards assoc...

Page 2: ...ler Secure the device against accidental contact Before working on the system machine wait until all parts have come to a standstill WARNING Rotating device Long hair and dangling items of clothing jewelry and the like can become entangled and be pulled into the device Injuries can result Do not wear any loose fitting or dangling clothing or jewelry while working on rotating parts Protect long hai...

Page 3: ...Nominal data Operating the device with all protective devices Following the operating instructions Improper use In particular operating the device in the following ways is prohibited and could be hazardous Operating the device in an unbalanced state e g due to dirt deposits or ice formation Opening the terminal box during operation Conveying air that contains abrasive particles Conveying highly co...

Page 4: ...al operating instructions 3 TECHNICAL DATA 3 1 Product drawing All dimensions in mm 1 Direction of air flow V 2 Tightening torque 0 5 0 1 Nm 3 Cable diameter max 7 5 mm tightening torque 1 3 0 2 Nm Item no 12325 5 9970 ENU Change 88936 Approved 2016 04 18 Page 4 10 ...

Page 5: ...al H protection class F2 2 Installation position Any Condensation drainage holes None Mode S1 Motor bearing Ball bearing with low temperature lubricant Touch current according to IEC 60990 measuring circuit Fig 4 TN system 0 75 mA Electrical hookup Via terminal box capacitor integrated and connected Motor protection Thermal overload protector TOP internally connected with cable Axial Protection cl...

Page 6: ...the data on the nameplate match the connection data and the data for the operating capacitor Before connecting the device make sure the power supply matches the device voltage Only use cables designed for the current level indicated on the nameplate For determining the cross section note the sizing criteria according to EN 61800 5 1 The protective earth must have a cross section equal to or greate...

Page 7: ...e ends fan out The terminal strip is equipped with a penetration guard Insert the leads until they meet resistance Seal the terminal box 4 3 3 Cable routing Water must be prevented from reaching the cable gland along the cable Fans installed lying flat Make sure the cable is routed in a U shaped loop Fig 2 Fan installed lying flat cable routed in a U shaped loop Fans installed upright When routing...

Page 8: ...nstructions S4E300 AS72 57 Translation of the original operating instructions 4 4 Connection diagram L U1 blue Z brown N U2 black PE green yellow Item no 12325 5 9970 ENU Change 88936 Approved 2016 04 18 Page 8 10 ...

Page 9: ...er found Apply the nominal supply voltage 4 8 Switching off the device Disconnect the device from the power supply at the supply line s main switch When disconnecting be sure to disconnect the ground connection last 5 MAINTENANCE MALFUNCTIONS POSSIBLE CAUSES AND REMEDIES Do not perform any repairs on your device Send the device to ebm papst for repair or replacement WARNING Live terminals and conn...

Page 10: ...ountry specific legal requirements NOTE Country specific legal requirements Always observe the applicable country specific legal regulations with regard to the disposal of products or waste occurring in the various phases of the life cycle The corresponding disposal standards are also to be heeded 5 3 2 Disassembly Disassembly of the product must be performed or supervised by qualified personnel w...