background image

Operating instructions

R4E400-AR05-06

Translation of the original operating instructions

3.2 Nominal data

Motor

M4E094-FA

Phase

1~

1~

Nominal voltage / VAC

230

230

Frequency / Hz

50

60

Type of data definition

ml

ml

Valid for approval /
standard

CE

CE

Speed / min

-1

1355

1480

Power input / W

375

540

Current draw / A

1.75

2.4

Motor capacitor / µF

8

8

Capacitor voltage / VDB

400

400

Capacitor standard

P0 (CE)

P0 (CE)

Min. back pressure / Pa

0

0

Min. ambient temperature
/ °C

-40

-40

Max. ambient
temperature
/ °C

60

50

Starting current / A

3.7

3.3

Maximum safe operating
speed / min

-1

1750
@ 60 °C

1750
@ 60 °C

ml = Max. load · me = Max. efficiency · fa = Running at free air

cs = Customer specs · cu = Customer unit

Subject to alterations

3.3 Data according to ErP directive

Installation category

A

Efficiency category

Static

Variable speed drive

No

Specific ratio

*

1.00

*

Specific ratio = 1 + p

fs

/ 100 000 Pa

Actual

Request
2013

Request
2015

Overall efficiency η

es

/ %

43

43

47

Efficiency grade N

58

58

62

Power input P

e

/ kW

0.37

Air flow q

v

/ m³/h

1870

Pressure increase total p

sf

/ Pa

300

Speed n / min

-1

1355

Data definition with optimum efficiency.

The ErP data is determined using a motor-impeller combination in a standardised

measurement configuration.

3.4 Technical features

Mass

7 kg

Size

400 mm

Surface of rotor

Coated in black

Material of impeller

Aluminium sheet

Number of blades

6

Direction of rotation

Clockwise, seen on rotor

Type of protection

IP 54

Insulation class

"F"

Humidity class

F4-1

Mounting position

Any

Condensate discharge
holes

None

Operation mode

S1

Motor bearing

Ball bearing

Touch current acc.
IEC 60990 (measuring
network Fig. 4, TN
system)

<= 3.5 mA

Motor protection

Thermal overload protector (TOP)
brought out

Cable exit

Variable

Protection class

I (if protective earth is connected by
customer)

Product conforming
to standard

EN 60034-1 (2010); CE

Approval

CCC; EAC

For cyclic speed loads, note that the rotating parts of the device
are designed for maximum one million load cycles. If you have
specific questions, contact ebm-papst for support.

3.5 Mounting data

For depth of screw, see chapter 3.1 Product drawing

;

Secure the mounting screws against accidentally coming loose (e.g.
by using self-locking screws).

Strength class for
mounting screws

8.8

You can obtain additional mounting data from the product drawing if
necessary.

3.6 Transport and storage conditions

;

Use the device in accordance with its protection type.

Max. permissible
ambient motor temp.
(transp./ storage)

+80 °C

Min. permissible
ambient motor temp.
(transp./storage)

-40 °C

Item no. 11085-5-9970 · Revision 82623 · Release 2014-05-08 · Page 5 / 10

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Summary of Contents for R4E400-AR05-06

Page 1: ...staff Only authorised specialists are permitted to install the device to carry out a test run and to perform work on the electrical installation 1 3 Basic safety rules 1 1 3 Basic safety rules Any sa...

Page 2: ...t DANGER Rotating device Body parts that come into contact with the rotor and impeller can be injured Secure the device against accidental contact Before working on the system machine wait until all p...

Page 3: ...the following ways is particularly prohibited and may cause hazards Operating the device with an imbalance e g caused by dirt deposits or icing Moving air that contains abrasive particles Moving highl...

Page 4: ...on line silicone 6G 0 5 mm 6 x brass lead tips crimped 2 Accessory part Inlet nozzle 54476 2 4013 not included in scope of delivery 3 Depth of screw max 12 mm Item no 11085 5 9970 Revision 82623 Relea...

Page 5: ...rotor Coated in black Material of impeller Aluminium sheet Number of blades 6 Direction of rotation Clockwise seen on rotor Type of protection IP 54 Insulation class F Humidity class F4 1 Mounting pos...

Page 6: ...the supply voltage matches the operating voltage of the device Only use cables designed for current according to the type plate For determining the cross section follow the basic principles in accorda...

Page 7: ...ipped with thermal overload protectors to protect the devices Check to make sure that the thermal overload protector is correctly connected before each operation Failure to connect up the thermal over...

Page 8: ...ns 4 4 Connection screen TOP 2 x grey U1 blue Z brown U2 black PE green yellow Item no 11085 5 9970 Revision 82623 Release 2014 05 08 Page 8 10 ebm papst Mulfingen GmbH Co KG Bachm hle 2 D 74673 Mulfi...

Page 9: ...e minutes after disconnecting the voltage at all poles before opening the device CAUTION Electrical load on the capacitor after device is switched off Electric shock risk of injury Discharge the capac...

Page 10: ...be tested How to test Frequency Which measure Check the protective casing against accidental contact for damage and to ensure that it is intact Visual inspection At least every 6 months Repair or rep...

Reviews: