Operating instructions
R4E400-AR05-06
Translation of the original operating instructions
3.2 Nominal data
Motor
M4E094-FA
Phase
1~
1~
Nominal voltage / VAC
230
230
Frequency / Hz
50
60
Type of data definition
ml
ml
Valid for approval /
standard
CE
CE
Speed / min
-1
1355
1480
Power input / W
375
540
Current draw / A
1.75
2.4
Motor capacitor / µF
8
8
Capacitor voltage / VDB
400
400
Capacitor standard
P0 (CE)
P0 (CE)
Min. back pressure / Pa
0
0
Min. ambient temperature
/ °C
-40
-40
Max. ambient
temperature
/ °C
60
50
Starting current / A
3.7
3.3
Maximum safe operating
speed / min
-1
1750
@ 60 °C
1750
@ 60 °C
ml = Max. load · me = Max. efficiency · fa = Running at free air
cs = Customer specs · cu = Customer unit
Subject to alterations
3.3 Data according to ErP directive
Installation category
A
Efficiency category
Static
Variable speed drive
No
Specific ratio
*
1.00
*
Specific ratio = 1 + p
fs
/ 100 000 Pa
Actual
Request
2013
Request
2015
Overall efficiency η
es
/ %
43
43
47
Efficiency grade N
58
58
62
Power input P
e
/ kW
0.37
Air flow q
v
/ m³/h
1870
Pressure increase total p
sf
/ Pa
300
Speed n / min
-1
1355
Data definition with optimum efficiency.
The ErP data is determined using a motor-impeller combination in a standardised
measurement configuration.
3.4 Technical features
Mass
7 kg
Size
400 mm
Surface of rotor
Coated in black
Material of impeller
Aluminium sheet
Number of blades
6
Direction of rotation
Clockwise, seen on rotor
Type of protection
IP 54
Insulation class
"F"
Humidity class
F4-1
Mounting position
Any
Condensate discharge
holes
None
Operation mode
S1
Motor bearing
Ball bearing
Touch current acc.
IEC 60990 (measuring
network Fig. 4, TN
system)
<= 3.5 mA
Motor protection
Thermal overload protector (TOP)
brought out
Cable exit
Variable
Protection class
I (if protective earth is connected by
customer)
Product conforming
to standard
EN 60034-1 (2010); CE
Approval
CCC; EAC
For cyclic speed loads, note that the rotating parts of the device
are designed for maximum one million load cycles. If you have
specific questions, contact ebm-papst for support.
3.5 Mounting data
For depth of screw, see chapter 3.1 Product drawing
;
Secure the mounting screws against accidentally coming loose (e.g.
by using self-locking screws).
Strength class for
mounting screws
8.8
You can obtain additional mounting data from the product drawing if
necessary.
3.6 Transport and storage conditions
;
Use the device in accordance with its protection type.
Max. permissible
ambient motor temp.
(transp./ storage)
+80 °C
Min. permissible
ambient motor temp.
(transp./storage)
-40 °C
Item no. 11085-5-9970 · Revision 82623 · Release 2014-05-08 · Page 5 / 10
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com