ebm-papst R4E355-AG04-13 Operating Instructions Manual Download Page 4

Operating instructions

R4E355-AG04-13

Translation of the original operating instructions

3. TECHNICAL DATA

3.1 Product drawing

All dimensions in mm.

1

Accessory part: Inlet ring 51357-2-4013 not included in scope of delivery, other inlet rings on request

2

Max. clearance for screw 10 mm

3

Cable PFA AWG20, 4x crimped splices

4

Cable PVC AWG26, 3x crimped splices

Item no. 11853-5-9970 · ENU · Change 89188 · Approved 2016-08-26 · Page 4 / 9

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Summary of Contents for R4E355-AG04-13

Page 1: ...stalled operated maintained and otherwise used by suitably qualified trained and authorized technical staff Only authorized specialists are permitted to install the device to carry out a test run and...

Page 2: ...EMC compliant 1 7 Mechanical movement DANGER Rotating device Risk of injury to body parts coming into contact with the rotor or the impeller Secure the device against accidental contact Before workin...

Page 3: ...rticular operating the device in the following ways is prohibited and could be hazardous Operating the device in an unbalanced state e g due to dirt deposits or ice formation Resonant operation operat...

Page 4: ...4013 not included in scope of delivery other inlet rings on request 2 Max clearance for screw 10 mm 3 Cable PFA AWG20 4x crimped splices 4 Cable PVC AWG26 3x crimped splices Item no 11853 5 9970 ENU C...

Page 5: ...maximum of one million load cycles If you have special questions consult ebm papst for support 3 4 Mounting data For screw clearance see Chapter 3 1 Product drawing Secure the screws against unintent...

Page 6: ...he sizing criteria according to EN 61800 5 1 The protective earth must have a cross section equal to or greater than that of the phase conductor We recommend the use of 105 C cables Ensure that the mi...

Page 7: ...diagram U1 blue Z brown U2 black PE green yellow 2 Hall IC circuit 2 1 Hall IC 2 2 red 5 V 2 3 white out 2 4 black 0 V Item no 11853 5 9970 ENU Change 89188 Approved 2016 08 26 Page 7 9 ebm papst Mul...

Page 8: ...MAINTENANCE MALFUNCTIONS POSSIBLE CAUSES AND REMEDIES Do not perform any repairs on your device Send the device to ebm papst for repair or replacement WARNING Live terminals and connections even with...

Page 9: ...1 Country specific legal requirements NOTE Country specific legal requirements Always observe the applicable country specific legal regulations with regard to the disposal of products or waste occurri...