ebm-papst R4D450-AK01-01 Operating Instructions Manual Download Page 5

Operating instructions

R4D450-AK01-01

Translation of the original operating instructions

3.2 Nominal data

Motor

M4D110-GF

Phase

3~

3~

3~

3~

Nominal voltage / VAC

230

230

277

400

Wiring

Δ

Δ

Δ

Y

Frequency / Hz

50

60

60

50

Method of obtaining
data

ml

ml

ml

ml

Valid for approval/
standard

CE

CE

CE

CE

Speed (rpm) / min

-1

1350

1490

1580

1350

Power consumption / W

740

1090

1200

740

Current draw / A

2.6

3.32

3.2

1.5

Min. back pressure / Pa

0

0

0

0

Min. ambient
temperature / °C

-40

-40

-40

-40

Max. ambient
temperature / °C

80

50

50

80

Starting current / A

10.6

9.7

12.1

6.1

Max. safe operating
speed (rpm) /
min

-1

2285

2285

2285

2285

Phase

3~

3~

Nominal voltage / VAC

400

480

Wiring

Y

Y

Frequency / Hz

60

60

Method of obtaining
data

ml

ml

Valid for approval/
standard

CE

CE

Speed (rpm) / min

-1

1490

1580

Power consumption / W

1090

1200

Current draw / A

1.92

1.85

Min. back pressure / Pa

0

0

Min. ambient
temperature / °C

-40

-40

Max. ambient
temperature / °C

50

50

Starting current / A

5.6

7.0

Max. safe operating
speed (rpm) /
min

-1

2285

2285

ml = Max. load · me = Max. efficiency · fa = Free air

cs = Customer specification · ce = Customer equipment

Subject to change

3.3 Data according to Commission Regulation (EU) 327/
2011

Actual

Req. 2015

01 Overall efficiency η

es

/ %

50

50

02 Measurement category

A

03 Efficiency category

Static

04 Efficiency grade N

62

62

05 Variable speed drive

No

06 Year of manufacture

The year of manufacture is specified on the
product's rating label.

07 Manufacturer

ebm-papst Mulfingen GmbH & Co. KG
Amtsgericht (court of registration) Stuttgart
· HRA 590344
D-74673 Mulfingen

08 Type

R4D450-AK01-01

09 Power consumption P

e

/ kW

0.72

09 Air flow q

v

/ m³/h

3515

09 Pressure increase total p

sf

/

Pa

370

10 Speed (rpm) n / min

-1

1350

11 Specific ratio

*

1.00

12 Recycling/disposal

Information on recycling and disposal is
provided in the operating instructions.

13 Maintenance

Information on installation, operation and
maintenance is provided in the operating
instructions.

14 Additional components

Components used to calculate the energy
efficiency that are not apparent from the
measurement category are detailed in the
CE declaration.

*

Specific ratio = 1 + p

fs

/ 100 000 Pa

Data obtained at optimum efficiency level. The ErP data is determined using a motor-impeller

combination in a standardized measurement setup.

3.4 Technical description

Weight

12 kg

Fan size

450 mm

Rotor surface

Cast in aluminum

Impeller material

Sheet aluminum

Number of blades

6

Direction of rotation

Clockwise, viewed toward rotor

Degree of protection

IP54

Insulation class

"F"

Moisture (F) /
Environmental (H)
protection class

F3-1

Installation position

Shaft horizontal or rotor on bottom; rotor
on top on request

Condensation
drainage holes

On rotor side

Mode

S1

Motor bearing

Ball bearing

Touch current
according to IEC
60990 (measuring
circuit Fig. 4, TN
system)

<= 3.5 mA

Motor protection

Thermal overload protector (TOP) with
basic insulation

Protection class

I (with customer connection of protective
earth)

Conformity with
standards

EN 61800-5-1; CE

Approval

CCC; UL 1004-1; VDE; EAC; CSA
C22.2 No. 100

Item no. 11147-5-9970 · ENU · Change 90169 · Approved 2016-08-29 · Page 5 / 11

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Summary of Contents for R4D450-AK01-01

Page 1: ...rated maintained and otherwise used by suitably qualified trained and authorized technical staff Only authorized specialists are permitted to install the device to carry out a test run and to perform...

Page 2: ...e rotor or the impeller Secure the device against accidental contact Before working on the system machine wait until all parts have come to a standstill WARNING Rotating device Long hair and dangling...

Page 3: ...he following ways is prohibited and could be hazardous Operating the device in an unbalanced state e g due to dirt deposits or ice formation Resonant operation operation with severe vibration This als...

Page 4: ...ring 63045 2 4013 not included in scope of delivery other inlet rings on request 2 Max clearance for screw 12 mm 3 Cable silicone 9G0 75 mm 9 x crimped splices Item no 11147 5 9970 ENU Change 90169 Ap...

Page 5: ...3 Mulfingen 08 Type R4D450 AK01 01 09 Power consumption Pe kW 0 72 09 Air flow qv m h 3515 09 Pressure increase total psf Pa 370 10 Speed rpm n min 1 1350 11 Specific ratio 1 00 12 Recycling disposal...

Page 6: ...ation until all fastening screws have been tightened 4 2 Electrical connection DANGER Voltage on the device Electric shock Always connect a protective earth first Check the protective earth DANGER Fau...

Page 7: ...n all poles phase phase and phase ground between the drive and the motor During operation with variable frequency drives an all pole sine filter protects the motor against high voltage transients that...

Page 8: ...ersing two phases Delta connection Y Star connection L1 black L2 blue L3 brown U1 black V1 blue W1 brown U2 green V2 white W2 yellow TOP gray Item no 11147 5 9970 ENU Change 90169 Approved 2016 08 29...

Page 9: ...LFUNCTIONS POSSIBLE CAUSES AND REMEDIES Do not perform any repairs on your device Send the device to ebm papst for repair or replacement WARNING Live terminals and connections even with device switche...

Page 10: ...necessary replace impeller 5 4 Disposal For ebm papst environmental protection and resource preservation are top priority corporate goals ebm papst operates an environmental management system which is...

Page 11: ...aterials and are therefore to be treated in the same manner The materials concerned are as follows Miscellaneous insulators used in the terminal box Power cables Cables for internal wiring Electrolyti...

Reviews: