ebm-papst R3G310-AL09-30 Operating Instructions Manual Download Page 4

Operating instructions

R3G310-AL09-30

Translation of the original operating instructions

3. TECHNICAL DATA

3.1 Product drawing

All dimensions in mm.

1

Accessory part: inlet ring 31050-2-4013 not included in scope of delivery

2

Max. clearance for screw 14 mm

3

Cable PVC AWG16, 4x crimped ferrules

Item no. 50837-5-9970 · ENU · Change 229907 · Approved 2021-09-23 · Page 4 / 10

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Summary of Contents for R3G310-AL09-30

Page 1: ...Only authorized specialists are permitted to install the device to carry out a test run and to perform work on the electrical installation 1 3 Basic safety rules 1 1 3 Basic safety rules The safety ha...

Page 2: ...ulled into the device Injuries can result Do not wear any loose fitting or dangling clothing or jewelry while working on rotating parts Protect long hair with a cap 1 8 Emissions WARNING Depending on...

Page 3: ...hazardous Operating the device in an unbalanced state e g due to dirt deposits or ice formation Resonant operation operation with severe vibration This also includes vibration transmitted to the fan...

Page 4: ...cessory part inlet ring 31050 2 4013 not included in scope of delivery 2 Max clearance for screw 14 mm 3 Cable PVC AWG16 4x crimped ferrules Item no 50837 5 9970 ENU Change 229907 Approved 2021 09 23...

Page 5: ...n of rotation Clockwise viewed toward rotor Degree of protection IP42 Insulation class B Moisture F Environmental H protection class H1 Installation position Any Condensation drainage holes None Mode...

Page 6: ...he device is securely positioned at its place of installation until all fastening screws have been tightened The fan must not be strained on fastening 4 2 Electrical connection CAUTION Voltage The fan...

Page 7: ...ting instructions 4 4 Connection diagram Drawing preliminary Item no 50837 5 9970 ENU Change 229907 Approved 2021 09 23 Page 7 10 ebm papst Mulfingen GmbH Co KG Bachm hle 2 D 74673 Mulfingen Phone 49...

Page 8: ...d remedies 4 7 Switching off the device Switching off the device during operation Switch off the device via the control input Do not switch the motor e g in cyclic operation on and off via power suppl...

Page 9: ...sible Do not clean the device using a water jet or high pressure cleaner Do not use any acid alkali or solvent basedcleaning agents Do not use any pointed or sharp edged objects for cleaning Completel...

Page 10: ...nts could drop off during disassembly This can result in fatal or serious injury and material damage Secure components before unfastening to stop them falling 5 4 3 Component disposal The products are...