ebm-papst R3G280-RU26-81 Operating Instructions Manual Download Page 6

Operating instructions

R3G280-RU26-81

Translation of the original operating instructions

3.2 Nominal data

Motor

M3G084-CF

Nominal voltage / VDC

26

Nominal voltage
range / VDC

16 .. 32

Type of data definition

fa

Speed (rpm) / min

-1

2350

Power input / W

252

Current draw / A

10.5

Min. ambient
temperature / °C

-40

Max. ambient
temperature / °C

70

ml = Max. load · me = Max. efficiency · fa = Running at free air

cs = Customer specs · cu = Customer unit

Subject to alterations

3.3 Data in accordance with ecodesign regulation EU 327/
2011

Actual

Request 2015

01 Overall efficiency η

es

/ %

66.3

46.2

02 Measurement category

A

03 Efficiency category

Static

04 Efficiency grade N

82.1

62

05 Variable speed drive

Yes

06 Year of manufacture

The year of manufacture is specified on the
rating plate on the product.

07 Manufacturer

ebm-papst Mulfingen GmbH & Co. KG
County court Stuttgart · HRA 590344
D-74673 Mulfingen

08 Type

R3G280-RU26-81

09 Power input P

e

/ kW

0.31

09 Air flow q

v

/ m³/h

1600

09 Pressure increase total p

fs

/

Pa

415

10 Speed (rpm) n / min

-1

2265

11 Specific ratio

*

1.00

12 Recycling/disposal

Information on recycling and disposal is
provided in the operating instructions.

13 Maintenance

Information on installation, operation and
maintenance is provided in the operating
instructions.

14 Additional components

Components used to calculate the energy
efficiency that are not apparent from the
measurement category are detailed in the
CE declaration.

*

Specific ratio = 1 + p

fs

/ 100 000 Pa

Data definition with optimum efficiency. The indicated efficiency values for obtaining

conformity with the Ecodesign Directive EU 327/2011 were achieved with defined air

conduction components (e.g. inlet nozzles). The dimensions are to be requested from ebm-

papst. If other air guide geometries are used on the installation side, the ebm-papst

evaluation loses its validity/conformity must be confirmed again. The product does not fall

within the scope of Regulation (EU) 2019/1781 due to the exception specified in Article 2(2a)

(motors completely integrated into a product).

3.4 Technical features

Mass

3.06 kg

Size

280 mm

Motor size

84

Surface of rotor

Coated in black

Material of electronics
housing

Die-cast aluminium, coated in black

Material of impeller

PA UL94 V0 plastic

Number of blades

6

Direction of rotation

Clockwise, seen on rotor

Type of protection

Motor IP24 KM, electronics IP6K9K
(mating connector fitted)

Insulation class

"B"

Humidity (F) /
environmental
protection class (H)

H3

Mounting position

Any

Condensation
drainage holes

None

Cooling bore / aperture

Rotor-side

Operation mode

S1

Motor bearing

Ball bearing; (sealed)

Technical features

- Lowering input
- Error output (high-side switch)
- INVLIN (control input, inverse linear)
- Output limit
-Load dump (58 V)
- Motor current limit
- Soft start
- Control input 0-10 VDC / PWM
- Temperature derating
- Overvoltage detection
- Over-temperature protected electronics
- Line undervoltage detection
- Reverse polarity protection

Electrical connection

Standby current less than 500 µA

Cable exit

Lateral

Safety classification

III; Requires supply with safety extra-
low voltage SELV.
This component to be built-in can have
several local safety classifications.
This specification relates to the basic
design of this component.
The final protection class is based on
the intended installation and connection of
the components.

Product conforming
to standard

EN 15085-1, CPC3; EN 45545-2, HL3;
EN 50155; EN 61373, Cat. 1B; CE

Approval

EAC

For cyclic speed loads, note that the rotating parts of the device
are designed for maximum one million load cycles. If you have
specific questions, contact ebm-papst for support.

;

Use the device in accordance with its protection type.

Item no. 52474-5-9970 · ENG · Revision 234450 · Release 2021-11-09 · Page 6 / 12

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Summary of Contents for R3G280-RU26-81

Page 1: ...ll the device to carry out a test run and to perform work on the electrical installation 1 3 Basic safety rules 1 1 3 Basic safety rules Any safety hazards stemming from the device must be re evaluate...

Page 2: ...come entangled and be pulled into the device Risk of injury Do not wear any loose fitting or dangling clothing or jewellery while working on rotating parts Protect long hair with a cap 1 8 Emission WA...

Page 3: ...lowing ways is particularly prohibited and may cause hazards Operating the device with an imbalance e g caused by dirt deposits or icing Resonance mode operation with heavy vibrations These also inclu...

Page 4: ...t hole prepared for self tapping M5 screw 3 Depth of screw max 8 mm pilot hole prepared for self tapping M4 screw 4 Depth of screw max 12 mm pilot hole prepared for self tapping M6 screw 5 Connection...

Page 5: ...structions All measures have the unit mm Inlet nozzle 28000 2 4013 Item no 52474 5 9970 ENG Revision 234450 Release 2021 11 09 Page 5 12 ebm papst Mulfingen GmbH Co KG Bachm hle 2 D 74673 Mulfingen Ph...

Page 6: ...mity must be confirmed again The product does not fall within the scope of Regulation EU 2019 1781 due to the exception specified in Article 2 2a motors completely integrated into a product 3 4 Techni...

Page 7: ...e fan from system components If the fan is connected to air ducts it should isolated from vibrations for example using compensators or similar elements Fasten the fan to the substructure without disto...

Page 8: ...standards and the type of protection in your end device after you have installed the ebm papst device Connect the connection lines to the mating connectors 4 3 2 Establish supply connections Check the...

Page 9: ...e of PWM signal is halved 4 0 10 V PWM yellow Control input Ri 47 k 0 10 V typ 1 V n 0 1 5 V n min 10 V n max PWM amplitude 10 V 1 50 kHz typ 5 n 0 15 n min 100 n max 5 DIAG white Diagnostic output op...

Page 10: ...the device Switching off the device during operation Switch off the device via the control input Do not switch the motor e g in cyclic operation on and off via power supply Switching off the device fo...

Page 11: ...At least every 6 months Repair or replacement of the device Check the device for damage to blades and housing Visual inspection At least every 6 months Replacement of the device Mounting the connecti...

Page 12: ...external rotor motors from ebm papst Mulfingen GmbH Co KG Ferrite magnets can be disposed of in the same way as normal iron and steel Electrical insulating materials on the product in cables and wires...