4.4 Connection screen

Line

No.

Signal

Colour

Function / assignment

CON10 L

black

Power supply 230 VAC, 50-60 Hz, for voltage range refer to rating plate

CON11 N

blue

Neutral conductor

CON12 PE

green/
yellow

Protective earth

1

GND

blue

GND - Connection for control interface

2

0- 10V PWM

yellow

Control input 0 - 10 V or PWM, electrically isolated

3

10V/ max 1.1mA

red

Voltage output 10V/ 1.1mA, electrically isolated, not short-circuit-proof.

4

Tach

white

Tach output: open collector, 1 pulse per revolution, electrically isolated

Item no. 51152-5-9970 · Revision 75542 · Release 2012-11-06 · Page 7 / 10

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Summary of Contents for R3G250-RE09-07

Page 1: ...sed specialist personnel are permitted to transport unpack assemble operate or maintain the device or to use it in any other manner 1 3 Basic safety rules 1 1 3 Basic safety rules Any safety hazards s...

Page 2: ...ire setup is EMC compliant 1 7 Mechanical movement DANGER Rotating device Body parts that come into contact with the rotor and impeller can be injured Secure the device against accidental contact Befo...

Page 3: ...the following ways is particularly prohibited and may cause hazards Operating the device with an imbalance e g caused by dirt deposits or icing Moving air that contains abrasive particles Moving highl...

Page 4: ...n the standard scope of delivery 2 Connection line PVC 4X 0 5 mm 4 x brass lead tips crimped 3 Connection line PVC 3G 0 5 mm 3 x brass lead tips crimped 4 Depth of screw max 10 mm 5 Depth of screw max...

Page 5: ...or on bottom rotor on top on request Condensate discharge holes None open rotor Operation mode S1 Motor bearing Ball bearing Technical features Output 10 VDC max 1 1 mA Tach output Motor current limit...

Page 6: ...e device Only use cables designed for current according to the type plate For determining the cross section follow the basic principles in accordance with EN 61800 5 1 The protective earth must have a...

Page 7: ...rth 1 GND blue GND Connection for control interface 2 0 10V PWM yellow Control input 0 10 V or PWM electrically isolated 3 10V max 1 1mA red Voltage output 10V 1 1mA electrically isolated not short ci...

Page 8: ...e device by changing the input signal 4 7 Switching off the device Switching off the device during operation Switch on the device via the control input Do not switch the motor e g in cyclic operation...

Page 9: ...ise correct connection see connection diagram Overtemperature of electronics motor Insufficient cooling Improve cooling Let the device cool down To reset the error message switch off the mains supply...

Page 10: ...the wires for damage Visual inspection At least every 6 months Replace wires Impeller for wear deposits corrosion and damage Visual inspection At least every 6 months Clean or replace impeller Item n...

Page 11: ...Mouser Electronics Authorized Distributor Click to View Pricing Inventory Delivery Lifecycle Information ebm papst R3G250 RE09 07...