ebm-papst R3G190-RG19-05 Operating Instructions Manual Download Page 5

Operating instructions

R3G190-RG19-05

Translation of the original operating instructions

All dimensions in mm.

1

Accessory part: inlet ring 09576-2-4013 not included in scope of delivery

Item no. 56286-5-9970 · ENU · Change 200888 · Approved 2021-11-23 · Page 5 / 12

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Summary of Contents for R3G190-RG19-05

Page 1: ...thorized technical staff Only authorized specialists are permitted to install the device to carry out a test run and to perform work on the electrical installation 1 3 Basic safety rules 1 1 3 Basic s...

Page 2: ...y that the entire setup is EMC compliant 1 7 Mechanical movement DANGER Rotating device Risk of injury to body parts coming into contact with the rotor or the impeller Secure the device against accide...

Page 3: ...prohibited and could be hazardous Operating the device in an unbalanced state e g due to dirt deposits or ice formation Resonant operation operation with severe vibration This also includes vibration...

Page 4: ...9576 2 4013 not included in scope of delivery 2 Max clearance for screw 10 mm 3 Max clearance for screw 5 mm 4 Cable PVC AWG20 3x splice 5 Cable PVC AWG22 3x splice Item no 56286 5 9970 ENU Change 200...

Page 5: ...sions in mm 1 Accessory part inlet ring 09576 2 4013 not included in scope of delivery Item no 56286 5 9970 ENU Change 200888 Approved 2021 11 23 Page 5 12 ebm papst Mulfingen GmbH Co KG Bachm hle 2 D...

Page 6: ...tended installation and connection Conformity with standards EN 60034 1 EN 60204 1 EN 60335 1 CE Use the device in accordance with its degree of protection Information on surface quality The surfaces...

Page 7: ...Water ingress at the customer end of the cable can damage the device Make sure the end of the cable is connected in a dry environment Only connect the device to circuits that can be switched off with...

Page 8: ...current LRA is equal to or less than the nominal current FLA 4 3 Connecting the cables The device has external leads First connect the PE protective earth Connect the cables according to your applicat...

Page 9: ...see nameplate for voltage range 1 PE green yellow Protective earth 7 PWM yellow Control input PWM Isink 5 10 mA SELV adjustable curve 5 Tacho white Tach output open collector 1 pulse per revolution S...

Page 10: ...g in cyclic operation on and off via power supply Disconnect the device from the power supply When disconnecting be sure to disconnect the ground connection last 5 INTEGRATED PROTECTIVE FEATURES The...

Page 11: ...cement is necessary after that period contact ebm papst Adapt the maintenance intervals to the actual level of dust exposure 6 2 Safety inspection NOTE High voltage test The integrated EMC filter has...

Page 12: ...num Non ferrous metal e g motor windings Plastics particularly with brominated flame retardants in accordance with marking Insulating materials Cables and wires Electronic scrap e g circuit boards Onl...

Reviews: