ebm-papst R3G160-AC70-01 Operating Instructions Manual Download Page 8

Operating instructions

R3G160-AC70-01

Translation of the original operating instructions

4.4 Connection diagram

Drawing preliminary!

Not switchable via power supply. Restart via input voltage only after 5 minute delay.

No.

Conn.

Designation

Color

Function/assignment

4

L

black

Supply connection, power supply, phase, voltage range see nameplate, 50/60 Hz

3

N

blue

Supply connection, power supply, neutral conductor, voltage range see nameplate, 50/60 Hz

1

PE

green/
yellow

Ground connection

8

0-10 V / PWM

yellow

0-10 V / PWM control input, Ri=100 kΩ, SELV

9

Tacho

white

Tach output, open collector, 1 pulse per revolution, Isink max = 10 mA, SELV

11

+10 V

red

Fixed voltage output 10 VDC +/-3 %, Imax.= 1.1 mA, short-circuit-proof, power supply for ext.
devices (e.g. potentiometers), SELV

12

GND

blue

Reference ground for control interface, SELV

Item no. 52436-5-9970 · ENU · Change 204653 · Approved 2020-01-07 · Page 8 / 11

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Summary of Contents for R3G160-AC70-01

Page 1: ...authorized technical staff Only authorized specialists are permitted to install the device to carry out a test run and to perform work on the electrical installation 1 3 Basic safety rules 1 1 3 Basi...

Page 2: ...y that the entire setup is EMC compliant 1 7 Mechanical movement DANGER Rotating device Risk of injury to body parts coming into contact with the rotor or the impeller Secure the device against accide...

Page 3: ...prohibited and could be hazardous Operating the device in an unbalanced state e g due to dirt deposits or ice formation Resonant operation operation with severe vibration This also includes vibration...

Page 4: ...arance for screw 8 mm 3 Tapping hole ready for self tapping M4 screw max clearance for screw 6 mm 4 Clearance for screw 8 10 mm tightening torque 2 5 0 2 Nm gluing the screws is recommended 5 Cable PV...

Page 5: ...ds note that the rotating parts of the device are designed for a maximum of one million load cycles If you have special questions consult ebm papst for support Use the device in accordance with its de...

Page 6: ...ater ingress at the customer end of the cable can damage the device Make sure the end of the cable is connected in a dry environment Only connect the device to circuits that can be switched off with a...

Page 7: ...nt LRA is equal to or less than the nominal current FLA 4 3 Connecting the cables The device has external leads First connect the PE protective earth Connect the cables according to your application W...

Page 8: ...tage range see nameplate 50 60 Hz 1 PE green yellow Ground connection 8 0 10 V PWM yellow 0 10 V PWM control input Ri 100 k SELV 9 Tacho white Tach output open collector 1 pulse per revolution Isink m...

Page 9: ...g in cyclic operation on and off via power supply Disconnect the device from the power supply When disconnecting be sure to disconnect the ground connection last 5 INTEGRATED PROTECTIVE FEATURES The...

Page 10: ...ning does not eliminate vibrations the fan may need to be rebalanced To have it rebalanced contact ebm papst The fan is equipped with maintenance free ball bearings The lifetime lubrication of the bal...

Page 11: ...tallic materials are generally considered to be fully recyclable Separate the components for recycling into the following categories Steel and iron Aluminum Non ferrous metal e g motor windings Plasti...

Reviews: