ebm-papst R2E250-AW50-13 Operating Instructions Manual Download Page 5

Operating instructions

R2E250-AW50-13

Translation of the original operating instructions

3.2 Nominal data

Motor

M2E068-EC

Phase

1~

1~

1~

Nominal voltage / VAC

230

230

230

Frequency / Hz

50

60

60

Method of obtaining
data

fa

fa

fa

Valid for approval/
standard

-

-

UL 2111

Speed (rpm) / min

-1

2650

2870

2870

Power consumption / W

185

260

275

Current draw / A

0.81

1.14

1.16

Capacitor / µF

6

6

6

Capacitor voltage / VDB

400

400

400

Capacitor standard

UL

Min. back pressure / Pa

0

0

0

Min. ambient
temperature / °C

-25

-25

-25

Max. ambient
temperature / °C

70

55

55

ml = Max. load · me = Max. efficiency · fa = Free air

cs = Customer specification · ce = Customer equipment

Subject to change

3.3 Technical description

Weight

3.2 kg

Size

250 mm

Motor size

68

Rotor surface

Painted black

Impeller material

Sheet aluminum

Number of blades

11

Direction of rotation

Clockwise, viewed toward rotor

Degree of protection

IP44; installation- and position-dependent
as per EN 60034-5

Insulation class

"F"

Moisture (F) /
Environmental (H)
protection class

H1; F1-1

Installation position

Shaft horizontal or rotor on bottom; rotor
on top on request

Condensation
drainage holes

On rotor side

Mode

S1

Motor bearing

Ball bearing

Touch current
according to IEC
60990 (measuring
circuit Fig. 4, TN
system)

< 0.75 mA

Motor protection

Thermal overload protector (TOP)
internally connected

with cable

Variable

Protection class

I (with customer connection of protective
earth)

Motor capacitor
according to EN 60252-
1 in safety protection
class

S0

Conformity with
standards

EN 60034-1; EN 60204-1

Approval

UL 1004-3; CSA C22.2 No. 77; CCC

With regard to cyclic speed loads, note that the rotating parts of
the device are designed for a maximum of one million load
cycles. If you have special questions, consult ebm-papst for
support.

;

Use the device in accordance with its degree of protection.

Information on surface quality

The surfaces of the products conform to the generally applicable industrial
standard. The surface quality may change during the production period.
This has no effect on strength, dimensional stability and dimensional
accuracy.
The color pigments in the paints used perceptibly react to UV light over
the course of time. This does not however in any way affect the
technical properties of the products. The product is to be protected against
UV radiation to prevent the formation of patches and fading. Changes in
color are not a reason for complaint and are not covered by the warranty.

3.4 Mounting data

;

Secure the screws against unintentional loosening (e.g. use self-
locking screws).

For screw clearance, see Chapter 3.1 Product drawing

Strength class of
screws

8.8

Any further mounting data required can be taken from the product
drawing or Section Chapter 4.1 Mechanical connection.

3.5 Transport and storage conditions

Max. permitted
ambient temp. for
motor (transport/
storage)

+ 80 °C

Min. permitted
ambient temp. for
motor (transport/
storage)

- 40 °C

Item no. 11419-5-9970 · ENU · Change 99365 · Approved 2018-04-27 · Page 5 / 10

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Summary of Contents for R2E250-AW50-13

Page 1: ...ed by suitably qualified trained and authorized technical staff Only authorized specialists are permitted to install the device to carry out a test run and to perform work on the electrical installati...

Page 2: ...coming into contact with the rotor or the impeller Secure the device against accidental contact Before working on the system machine wait until all parts have come to a standstill WARNING Rotating de...

Page 3: ...ticular operating the device in the following ways is prohibited and could be hazardous Operating the device in an unbalanced state e g due to dirt deposits or ice formation Resonant operation operati...

Page 4: ...ll IC Raychem cable 3X AWG24 connector housing Molex no 70107 0037 with 3x plug pin Molex no 16 02 0078 crimped 3 1 5 V red 3 2 out white 3 3 0 V black 4 Cable PFA 4G AWG20 4x crimped splices Capacito...

Page 5: ...ection class S0 Conformity with standards EN 60034 1 EN 60204 1 Approval UL 1004 3 CSA C22 2 No 77 CCC With regard to cyclic speed loads note that the rotating parts of the device are designed for a m...

Page 6: ...nnected in a dry environment Only connect the device to circuits that can be switched off with an all pole disconnection switch 4 2 1 Requirements Check whether the information on the nameplate matche...

Page 7: ...ion When doing so observe Chapter 4 5 Connection diagram 4 4 Connection of the Hall IC The device has external leads Connect the cables according to your application When doing so observe Chapter 4 5...

Page 8: ...diagram U1 blue Z brown U2 black PE green yellow 2 Hall IC circuit 2 1 Hall IC 2 2 red 5 V 2 3 white out 2 4 black 0 V Item no 11419 5 9970 ENU Change 99365 Approved 2018 04 27 Page 8 10 ebm papst Mul...

Page 9: ...MAINTENANCE MALFUNCTIONS POSSIBLE CAUSES AND REMEDIES Do not perform any repairs on your device Send the device to ebm papst for repair or replacement WARNING Live terminals and connections even with...

Page 10: ...ents Always observe the applicable country specific legal regulations with regard to the disposal of products or waste occurring in the various phases of the life cycle The corresponding disposal stan...

Reviews: