ebm-papst R2E225-AT55-12 Operating Instructions Manual Download Page 5

Operating instructions

R2E225-AT55-12

Translation of the original operating instructions

3.2 Nominal data

Motor

M2E068-DF

Phase

1~

1~

1~

Nominal voltage / VAC

115

115

115

Frequency / Hz

50

60

60

Type of data definition

fa

fa

fa

Valid for approval /
standard

CE

CE

UL 2111

Speed / min

-1

2500

2600

2600

Power input / W

85

120

125

Current draw / A

0.75

1.05

1.05

Motor capacitor / µF

8

8

8

Capacitor voltage / VDB

220

220

220

Min. back pressure / Pa

0

0

0

Max. ambient
temperature / °C

60

55

55

ml = max. load · me = max. efficiency · fa = running at free air

cs = customer specs · cu = customer unit

Subject to alterations

3.3 Technical features

Mass

2.3 kg

Size

225 mm

Surface of rotor

Uncoated

Material of impeller

Plastic PA6, fibreglass-reinforced

Number of blades

11

Direction of rotation

Clockwise, seen on rotor

Type of protection

IP 44; Depending on installation and
position

Insulation class

"B"

Humidity class

F0

Mounting position

Any

Condensate discharge
holes

None

Operation mode

S1

Motor bearing

Ball bearing

Touch current acc.
IEC 60990 (measuring
network Fig. 4, TN
system)

< 0.75 mA

Motor protection

Thermal overload protector (TOP) wired
internally

Cable exit

Axial

Protection class

I (if protective earth is connected by
customer)

Product conforming
to standard

EN 60335-1; CE

Approval

UL 2111; CSA C22.2 Nr.77

For cyclic speed loads, note that the rotating parts of the device
are designed for maximum one million load cycles. If you have
specific questions, contact ebm-papst for support.

3.4 Mounting data

For depth of screw, see chapter 3.1 Product drawing

;

Secure the mounting screws against accidentally coming loose (e.g.
by using self-locking screws).

Strength class for
mounting screws

8.8

You can obtain additional mounting data from the product drawing if
necessary.

3.5 Transport and storage conditions

;

Use the device in accordance with its protection type.

Max. permissible
ambient motor temp.
(transp./ storage)

+ 80 °C

Min. permissible
ambient motor temp.
(transp./storage)

- 40 °C

Item no. 11315-5-9970 · Revision 73098 · Release 2011-01-21 · Page 5 / 9

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Summary of Contents for R2E225-AT55-12

Page 1: ...he electrical system Only trained and authorised specialist personnel are permitted to transport unpack assemble operate or maintain the device or to use it in any other manner 1 3 Basic safety rules...

Page 2: ...could become entangled and pulled into the device You could be injured Do not wear any loose clothing or jewellery while working on rotating parts Protect long hair by wearing a cap 1 7 Emission WARNI...

Page 3: ...the following ways is particularly prohibited and may cause hazards Operating the device with an imbalance e g caused by dirt deposits or icing Moving air that contains abrasive particles Moving highl...

Page 4: ...on line PVC AWG20 4x brass lead tips crimped 2 Accessory part Inlet nozzle 96358 2 4013 not included in the standard scope of delivery 3 Depth of screw max 5 mm Item no 11315 5 9970 Revision 73098 Rel...

Page 5: ...earing Touch current acc IEC 60990 measuring network Fig 4 TN system 0 75 mA Motor protection Thermal overload protector TOP wired internally Cable exit Axial Protection class I if protective earth is...

Page 6: ...dry environment Connect the device only to circuits that can be switched off using an all pole disconnecting switch 4 2 1 Prerequisites Check whether the data on the type plate agree with the connect...

Page 7: ...tructions 4 4 Connection screen U1 blue Z brown U2 black PE green yellow Item no 11315 5 9970 Revision 73098 Release 2011 01 21 Page 7 9 ebm papst Mulfingen GmbH Co KG Bachm hle 2 D 74673 Mulfingen Ph...

Page 8: ...off Electric shock risk of injury Discharge the capacitors before working on the device CAUTION The motor restarts automatically when operating voltage is applied e g after a power failure Danger of i...

Page 9: ...epair or replacement of the device Check the device for damage to blades and housing Visual inspection At least every 6 months Replacement of the device Mounting the connection lines Visual inspection...

Reviews: