3.2 Nominal data

Motor

M2E068-EC

Phase

1~

Nominal voltage / VAC

240

Frequency / Hz

50

Method of obtaining
data

fa

Valid for approval/
standard

CE

Speed (rpm) / min

-1

2600

Power consumption / W

195

Current draw / A

0.82

Capacitor / µF

5

Capacitor voltage / VDB

400

Min. back pressure / Pa

0

Min. ambient
temperature / °C

-25

Max. ambient
temperature / °C

80

ml = Max. load · me = Max. efficiency · fa = Free air

cs = Customer specification · ce = Customer equipment

Subject to change

3.3 Technical description

Weight

4.01 kg

Size

225 mm

Motor size

68

Rotor surface

Unpainted

Motor suspension

Motor mounted with brackets on one side

Direction of rotation

Clockwise, viewed toward rotor

Degree of protection

IP20

Insulation class

"F"

Moisture (F) /
Environmental (H)
protection class

H0 - dry environment

Installation position

Shaft horizontal

Condensation
drainage holes

None

Mode

S1

Motor bearing

Ball bearing

Touch current
according to IEC
60990 (measuring
circuit Fig. 4, TN
system)

< 0.75 mA

Electrical hookup

Terminal strip; Via terminal strip

Motor protection

Thermal overload protector (TOP)
internally connected

with cable

Axial

Protection class

I (if protective earth is connected by
customer to the housing's connection point)

Conformity with
standards

CE

;

Use the device in accordance with its degree of protection.

Information on surface quality

The surfaces of the products conform to the generally applicable industrial
standard. The surface quality may change during the production period.
This has no effect on strength, dimensional stability and dimensional
accuracy.
The color pigments in the paints used perceptibly react to UV light over
the course of time. The product is to be protected against UV radiation to
prevent the formation of patches and fading. Changes in color are not a
reason for complaint and are not covered by the warranty. UV radiation
in the frequency range and the intensity of natural solar radiation has no
effect on the technical properties of the products.

3.4 Mounting data

Any further mounting data required can be taken from the product
drawing or Section Chapter 4.1 Mechanical connection.

Strength class of
screws

8.8

For screw clearance, see Chapter 3.1 Product drawing

;

Secure the screws against unintentional loosening (e.g. use self-
locking screws).

3.5 Transport and storage conditions

Max. permitted
ambient temp. for
motor (transport/
storage)

+ 80 °C

Min. permitted
ambient temp. for
motor (transport/
storage)

- 40 °C

Item no. 14585-5-9970 · ENU · Change 257459 · Approved 2022-05-06 · Page 5 / 11

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Summary of Contents for R2E225-AG03-11

Page 1: ...otherwise used by suitably qualified trained and authorized technical staff Only authorized specialists are permitted to install the device to carry out a test run and to perform work on the electrica...

Page 2: ...efore working on the system machine wait until all parts have come to a standstill WARNING Rotating device Long hair and dangling items of clothing jewelry and the like can become entangled and be pul...

Page 3: ...ing the device in an unbalanced state e g due to dirt deposits or ice formation Resonant operation operation with severe vibration This also includes vibration transmitted to the fan from the customer...

Page 4: ...lvanized 2 Centrifugal fan impeller sheet steel rust and acid resistant 3 1 L blue 3 2 N black 3 3 Z brown 4 M4 screw for fastening ground connector Max clearance for screw 5 mm Item no 14585 5 9970 E...

Page 5: ...connection point Conformity with standards CE Use the device in accordance with its degree of protection Information on surface quality The surfaces of the products conform to the generally applicable...

Page 6: ...re the end of the cable is connected in a dry environment Only connect the device to circuits that can be switched off with an all pole disconnection switch 4 2 1 Requirements Check whether the inform...

Page 7: ...device switched off Electric shock Wait five minutes after disconnecting the voltage at all poles before opening the device Insert the wires into the terminals see Chapter 4 4 Connection diagram Item...

Page 8: ...g instructions 4 4 Connection diagram U1 blue Z brown U2 black Item no 14585 5 9970 ENU Change 257459 Approved 2022 05 06 Page 8 11 ebm papst Mulfingen GmbH Co KG Bachm hle 2 D 74673 Mulfingen Phone 4...

Page 9: ...MAINTENANCE MALFUNCTIONS POSSIBLE CAUSES AND REMEDIES Do not perform any repairs on your device Send the device to ebm papst for repair or replacement WARNING Live terminals and connections even with...

Page 10: ...n Visual inspection At least every 6 months Replace device Abnormal bearing noise acoustic At least every 6 months Replace device 5 3 Disposal For ebm papst environmental protection and resource prese...

Page 11: ...ectrolytic capacitors Dispose of electronic components employing the proper procedures for electronic scrap Please contact ebm papst for any other questions on disposal Item no 14585 5 9970 ENU Change...

Reviews: