background image

Operating instructions

R2E150-AN91-05

Translation of the original operating instructions

3.2 Nominal data

Motor

M2E068-BF

Phase

1~

Nominal voltage / VAC

230

Frequency / Hz

50

Type of data definition

fa

Valid for approval /
standard

CE

Speed / min

-1

2400

Power input / W

32

Current draw / A

0.14

Motor capacitor / µF

1

Capacitor voltage / VDB

400

Min. back pressure / Pa

0

Max. ambient
temperature / °C

100

ml = max. load · me = max. efficiency · fa = running at free air

cs = customer specs · cu = customer unit

Subject to alterations

3.3 Technical features

Mass

2.0 kg

Size

150 mm

Surface of rotor

Uncoated

Material of impeller

Sheet steel, stainless

Housing material

Steel, phosphated and coated in black
plastic

Number of blades

6

Direction of rotation

Counter-clockwise, seen on rotor

Type of protection

IP 44; Depending on installation and
position

Insulation class

"F"

Humidity class

F0

Mounting position

any

Condensate discharge
holes

None

Operation mode

S1

Motor bearing

Ball bearing

Touch current acc.
IEC 60990 (measuring
network Fig. 4, TN
system)

< 0.75 mA

Motor protection

Thermal overload protector (TOP) wired
internally

Cable exit

Variable

Protection class

I (if protective earth is connected by
customer)

Product conforming
to standard

EN 60335-1; CE

For cyclic speed loads, note that the rotating parts of the device
are designed for maximum one million load cycles. If you have
specific questions, contact ebm-papst for support.

3.4 Mounting data

For depth of screw, see chapter 3.1 Product drawing

;

Secure the mounting screws against accidentally coming loose (e.g.
by using self-locking screws).

Strength class for
mounting screws

8.8

You can obtain additional mounting data from the product drawing if
necessary.

3.5 Transport and storage conditions

;

Use the device in accordance with its protection type.

Max. permissible
ambient motor temp.
(transp./ storage)

+ 80 °C

Min. permissible
ambient motor temp.
(transp./storage)

- 40 °C

Item no. 10691-5-9970 · Revision 68158 · Release 2012-02-22 · Page 5 / 9

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Summary of Contents for R2E150-AN91-05

Page 1: ...stem Only trained and authorised specialist personnel are permitted to transport unpack assemble operate or maintain the device or to use it in any other manner 1 3 Basic safety rules 1 1 3 Basic safe...

Page 2: ...could become entangled and pulled into the device You could be injured Do not wear any loose clothing or jewellery while working on rotating parts Protect long hair by wearing a cap 1 7 Emission WARNI...

Page 3: ...es in place Minding the operating instructions Improper use Using the device in the following ways is particularly prohibited and may cause hazards Operating the device with an imbalance e g caused by...

Page 4: ...measures have the unit mm 1 Connection line silicone 4x brass lead tips crimped 2 Connection line 3x brass lead tips crimped Item no 10691 5 9970 Revision 68158 Release 2012 02 22 Page 4 9 ebm papst M...

Page 5: ...bearing Touch current acc IEC 60990 measuring network Fig 4 TN system 0 75 mA Motor protection Thermal overload protector TOP wired internally Cable exit Variable Protection class I if protective eart...

Page 6: ...n all pole disconnecting switch 4 2 1 Prerequisites Check whether the data on the type plate agree with the connection data and the data of the operating capacitor Before connecting the device ensure...

Page 7: ...on diagram U1 blue Z brown U2 black PE green yellow 2 Hall IC circuit 2 1 Hall IC 2 2 red 5V 2 3 white out 2 4 black 0V Item no 10691 5 9970 Revision 68158 Release 2012 02 22 Page 7 9 ebm papst Mulfin...

Page 8: ...off Electric shock risk of injury Discharge the capacitors before working on the device CAUTION The motor restarts automatically when operating voltage is applied e g after a power failure Danger of i...

Page 9: ...nspection At least every 6 months Repair or replacement of the device Device for damage Visual inspection At least every 6 months Replace device Mounting the connection lines Visual inspection At leas...