3.2 Nominal data

Motor

M2E068-BF

Phase

1~

Nominal voltage / VAC

115

Frequency / Hz

60

Type of data definition

fa

Valid for approval /
standard

UL 2111

Speed / min

-1

-

Power input / W

40

Motor capacitor / µF

3

Capacitor voltage / VDB

220

Capacitor standard

UL

Min. back pressure / Pa

0

Min. ambient
temperature / °C

-25

Max. ambient
temperature / °C

80

ml = max. load · me = max. efficiency · fa = running at free air

cs = customer specs · cu = customer unit

Subject to alterations

3.3 Technical features

Mass

1.7 kg

Size

150 mm

Surface of rotor

Uncoated

Material of impeller

Sheet steel, stainless

Number of blades

6

Direction of rotation

Counter-clockwise, seen on rotor

Type of protection

IP 44; Depending on installation and
position

Insulation class

"B"

Humidity class

F0

Mounting position

Any

Operation mode

S1

Motor bearing

Ball bearing

Touch current acc.
IEC 60990 (measuring
network Fig. 4, TN
system)

< 0.75 mA

Motor protection

Thermal overload protector (TOP) wired
internally

Cable exit

Variable

Protection class

I (if protective earth is connected by
customer)

Product conforming
to standard

EN 60335-1; CE

Approval

UL 2111; CSA C22.2 Nr.77

For cyclic speed loads, note that the rotating parts of the device
are designed for maximum one million load cycles. If you have
specific questions, contact ebm-papst for support.

3.4 Mounting data

For depth of screw, see chapter 3.1 Product drawing

;

Secure the mounting screws against accidentally coming loose (e.g.
by using self-locking screws).

Strength class for
mounting screws

8.8

You can obtain additional mounting data from the product drawing if
necessary.

3.5 Transport and storage conditions

;

Use the device in accordance with its protection type.

Max. permissible
ambient motor temp.
(transp./ storage)

+ 80 °C

Min. permissible
ambient motor temp.
(transp./storage)

- 40 °C

Item no. 11216-5-9970 · Revision 72650 · Release 2012-02-22 · Page 5 / 9

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Summary of Contents for R2E150-AN89-11

Page 1: ...and authorised specialist personnel are permitted to transport unpack assemble operate or maintain the device or to use it in any other manner 1 3 Basic safety rules 1 1 3 Basic safety rules Any safet...

Page 2: ...could become entangled and pulled into the device You could be injured Do not wear any loose clothing or jewellery while working on rotating parts Protect long hair by wearing a cap 1 7 Emission WARNI...

Page 3: ...ith all protective features in place Minding the operating instructions Improper use Using the device in the following ways is particularly prohibited and may cause hazards Operating the device with a...

Page 4: ...tion line AWG20 1x contact stud 1x receptacle for tabs 160389 3 and 2x receptacle for tabs 3 160256 1 2 AMP connector shell 350766 4 with 3x plug pin 926885 1 Item no 11216 5 9970 Revision 72650 Relea...

Page 5: ...twork Fig 4 TN system 0 75 mA Motor protection Thermal overload protector TOP wired internally Cable exit Variable Protection class I if protective earth is connected by customer Product conforming to...

Page 6: ...ining the cross section follow the basic principles in accordance with EN 61800 5 1 The protective earth must have a cross section equal to or greater than the outer conductor cross section We recomme...

Page 7: ...on diagram U1 blue Z brown U2 black PE green yellow 2 Hall IC circuit 2 1 Hall IC 2 2 red 5V 2 3 white out 2 4 black 0V Item no 11216 5 9970 Revision 72650 Release 2012 02 22 Page 7 9 ebm papst Mulfin...

Page 8: ...off Electric shock risk of injury Discharge the capacitors before working on the device CAUTION The motor restarts automatically when operating voltage is applied e g after a power failure Danger of i...

Page 9: ...of the device Device for damage Visual inspection At least every 6 months Replace device Mounting the connection lines Visual inspection At least every 6 months Fasten Mounting of protective earth co...