Operating instructions
R2E150-AN89-11
Translation of the original operating instructions
3.2 Nominal data
Motor
M2E068-BF
Phase
1~
Nominal voltage / VAC
115
Frequency / Hz
60
Type of data definition
fa
Valid for approval /
standard
UL 2111
Speed / min
-1
-
Power input / W
40
Motor capacitor / µF
3
Capacitor voltage / VDB
220
Capacitor standard
UL
Min. back pressure / Pa
0
Min. ambient
temperature / °C
-25
Max. ambient
temperature / °C
80
ml = max. load · me = max. efficiency · fa = running at free air
cs = customer specs · cu = customer unit
Subject to alterations
3.3 Technical features
Mass
1.7 kg
Size
150 mm
Surface of rotor
Uncoated
Material of impeller
Sheet steel, stainless
Number of blades
6
Direction of rotation
Counter-clockwise, seen on rotor
Type of protection
IP 44; Depending on installation and
position
Insulation class
"B"
Humidity class
F0
Mounting position
Any
Operation mode
S1
Motor bearing
Ball bearing
Touch current acc.
IEC 60990 (measuring
network Fig. 4, TN
system)
< 0.75 mA
Motor protection
Thermal overload protector (TOP) wired
internally
Cable exit
Variable
Protection class
I (if protective earth is connected by
customer)
Product conforming
to standard
EN 60335-1; CE
Approval
UL 2111; CSA C22.2 Nr.77
For cyclic speed loads, note that the rotating parts of the device
are designed for maximum one million load cycles. If you have
specific questions, contact ebm-papst for support.
3.4 Mounting data
For depth of screw, see chapter 3.1 Product drawing
;
Secure the mounting screws against accidentally coming loose (e.g.
by using self-locking screws).
Strength class for
mounting screws
8.8
You can obtain additional mounting data from the product drawing if
necessary.
3.5 Transport and storage conditions
;
Use the device in accordance with its protection type.
Max. permissible
ambient motor temp.
(transp./ storage)
+ 80 °C
Min. permissible
ambient motor temp.
(transp./storage)
- 40 °C
Item no. 11216-5-9970 · Revision 72650 · Release 2012-02-22 · Page 5 / 9
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com