3.2 Nominal data
Motor
M2E068-CA
Phase
1~
Nominal voltage / VAC
230
Frequency / Hz
50
Method of obtaining
data
fa
Valid for approval/
standard
CE
Speed (rpm) / min
-1
1700
Power consumption / W
130
Current draw / A
0.57
Capacitor / µF
3
Capacitor voltage / VDB
450
Min. back pressure / Pa
0
Min. ambient
temperature / °C
-25
Max. ambient
temperature / °C
40
ml = Max. load · me = Max. efficiency · fa = Free air
cs = Customer specification · ce = Customer equipment
Subject to change
3.3 Technical description
Weight
1.4 kg
Fan size
140 mm
Rotor surface
Painted black
Impeller material
Sheet steel, galvanized
Direction of rotation
Clockwise, viewed toward rotor
Degree of protection
IP44; installation- and position-dependent
as per EN 60034-5
Insulation class
"B"
Moisture (F) /
Environmental (H)
protection class
H0+
Installation position
Shaft horizontal or rotor on bottom; rotor
on top on request
Condensation
drainage holes
On rotor side
Mode
S1
Motor bearing
Ball bearing
Touch current
according to IEC
60990 (measuring
circuit Fig. 4, TN
system)
< 0.75 mA
Motor protection
Temperature limiter manual reset
with cable
Variable
Protection class
I (with customer connection of protective
earth)
Conformity with
standards
EN 60335-1; CE
With regard to cyclic speed loads, note that the rotating parts of
the device are designed for a maximum of one million load
cycles. If you have special questions, consult ebm-papst for
support.
3.4 Mounting data
For screw clearance, see Chapter 3.1 Product drawing
;
Secure the screws against unintentional loosening (e.g. use self-
locking screws).
Any further mounting data required can be taken from the product drawing.
3.5 Transport and storage conditions
;
Use the device in accordance with its degree of protection.
Max. permitted
ambient temp. for
motor (transport/
storage)
+ 80 °C
Min. permitted
ambient temp. for
motor (transport/
storage)
- 40 °C
4. CONNECTION AND STARTUP
4.1 Mechanical connection
CAUTION
Cutting and crushing hazard when removing fan from
packaging
→ Carefully remove the device from its packaging, by the fan
impeller. Strictly avoid shocks.
→ Wear safety shoes and cut-resistant safety gloves.
;
Check the device for transport damage. Damaged devices are not to
be installed.
;
Install the undamaged device in accordance with your application.
CAUTION
Possible damage to the device
If the device slips during installation, serious damage can result.
→ Ensure that the device is securely positioned at its place of
installation until all fastening screws have been tightened.
4.2 Electrical connection
DANGER
Voltage on the device
Electric shock
→ Always connect a protective earth first.
→ Check the protective earth.
DANGER
Faulty insulation
Risk of fatal injury from electric shock
→ Use only cables that meet the specified installation
regulations for voltage, current, insulation material, capacity,
etc.
→ Route cables so that they cannot be touched by any
rotating parts.
Item no. 12350-5-9970 · ENU · Change 89188 · Approved 2016-04-18 · Page 5 / 9