Operating instructions

R2D250-RC10-11

Translation of the original operating instructions

3.2 Nominal data

Motor

M2D074-EI

Phase

3~

3~

3~

3~

Nominal voltage / VAC

400

400

400

400

Wiring

Δ

Y

Δ

Y

Frequency / Hz

50

50

60

60

Method of obtaining
data

ml

ml

ml

ml

Valid for approval/
standard

CE

CE

CE

CE

Speed (rpm) / min

-1

2700

2150

2950

2000

Power consumption / W

215

160

325

195

Current draw / A

0.36

0.24

0.51

0.3

Min. back pressure / Pa

0

0

0

0

Min. ambient
temperature / °C

-40

-40

-40

-40

Max. ambient
temperature / °C

80

80

75

75

Starting current / A

1.6

0.55

1.5

0.5

Phase

3~

3~

Nominal voltage / VAC

480

480

Wiring

Δ

Y

Frequency / Hz

60

60

Method of obtaining
data

ml

ml

Valid for approval/
standard

CE

CE

Speed (rpm) / min

-1

3150

2350

Power consumption / W

355

240

Current draw / A

0.48

0.32

Min. back pressure / Pa

0

0

Min. ambient
temperature / °C

-40

-40

Max. ambient
temperature / °C

75

75

Starting current / A

1.7

0.65

ml = Max. load · me = Max. efficiency · fa = Free air

cs = Customer specification · ce = Customer equipment

Subject to change

3.3 Data according to Commission Regulation (EU) 327/
2011

Actual

Req. 2015

01 Overall efficiency η

es

/ %

45.1

44.5

02 Measurement category

A

03 Efficiency category

Static

04 Efficiency grade N

62.6

62

05 Variable speed drive

No

06 Year of manufacture

The year of manufacture is specified on the
product's rating label.

07 Manufacturer

ebm-papst Mulfingen GmbH & Co. KG
Amtsgericht (court of registration) Stuttgart ·
HRA 590344
D-74673 Mulfingen

08 Type

R2D250-RC10-11

09 Power consumption P

e

/ kW

0.21

09 Air flow q

v

/ m³/h

905

09 Pressure increase total p

fs

/

Pa

387

10 Speed (rpm) n / min

-1

2690

11 Specific ratio

*

1.00

12 Recycling/disposal

Information on recycling and disposal is
provided in the operating instructions.

13 Maintenance

Information on installation, operation and
maintenance is provided in the operating
instructions.

14 Additional components

Components used to calculate the energy
efficiency that are not apparent from the
measurement category are detailed in the
CE declaration.

*

Specific ratio = 1 + p

fs

/ 100 000 Pa

Data obtained at optimum efficiency level. The efficiency values displayed for achieving

conformity with the Ecodesign Regulation EU 327/2011 has been reached with defined air

duct components (e.g. inlet rings). The dimensions must be requested from ebm-papst. If

other air conduction geometries are used on the installation side, the ebm-papst evaluation

loses its validity/the conformity must be confirmed again. The product does not fall within

the scope of Regulation (EU) 2019/1781 due to the exception specified in Article 2 (2a)

(motors completely integrated into a product).

3.4 Technical description

Weight

3.9 kg

Size

250 mm

Motor size

74

Rotor surface

Painted black

Impeller material

PA plastic, sheet-metal plate painted black

Number of blades

7

Direction of rotation

Clockwise, viewed toward rotor

Degree of protection

IP44

Insulation class

"F"

Moisture (F) /
Environmental (H)
protection class

H1+

Installation position

Shaft horizontal or rotor on bottom; rotor
on top on request

Condensation
drainage holes

On rotor side

Mode

S1

Motor bearing

Ball bearing; (sealed)

Touch current
according to IEC
60990 (measuring
circuit Fig. 4, TN
system)

< 0.75 mA

Motor protection

Thermal overload protector (TOP) with
basic insulation

with cable

Variable

Protection class
assignment

I; If a protective earth is connected by
the customer
This component for installation may
have several local protection classes.
This information relates to this
component’s basic design.
The final protection class is based on
the component’s intended installation and
connection.

Conformity with
standards

EN 15085-1, CPC3; EN 45545-2, HL3;
EN 50155; EN 61373, Cat. 1B; CE

Approval

EAC

Item no. 16617-5-9970 · ENU · Change 238450 · Approved 2021-11-11 · Page 6 / 12

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Summary of Contents for R2D250-RC10-11

Page 1: ...and authorized technical staff Only authorized specialists are permitted to install the device to carry out a test run and to perform work on the electrical installation 1 3 Basic safety rules 1 1 3...

Page 2: ...Verify that the entire setup is EMC compliant 1 7 Mechanical movement DANGER Rotating device Risk of injury to body parts coming into contact with the rotor or the impeller Secure the device against...

Page 3: ...following ways is prohibited and could be hazardous Operating the device in an unbalanced state e g due to dirt deposits or ice formation Resonant operation operation with severe vibration This also i...

Page 4: ...et ring 96420 2 4013 not included in scope of delivery 2 Max clearance for screw 10 mm 3 Cable halogen free railway application EN 45545 9G 0 5 mm 9x splice Item no 16617 5 9970 ENU Change 238450 Appr...

Page 5: ...ing instructions All dimensions in mm Inlet ring 96420 2 4013 Item no 16617 5 9970 ENU Change 238450 Approved 2021 11 11 Page 5 12 ebm papst Mulfingen GmbH Co KG Bachm hle 2 D 74673 Mulfingen Phone 49...

Page 6: ...mponents used to calculate the energy efficiency that are not apparent from the measurement category are detailed in the CE declaration Specific ratio 1 pfs 100 000 Pa Data obtained at optimum efficie...

Page 7: ...ce from its packaging by the fan impeller Strictly avoid shocks Wear safety shoes and cut resistant safety gloves NOTE Damage to the device from vibration Bearing damage shorter service life The fan m...

Page 8: ...le frequency drives install sinusoidal filters that work on all poles phase phase and phase ground between the drive and the motor During operation with variable frequency drives an all pole sine filt...

Page 9: ...phases Delta connection Y Star connection L1 black L2 blue L3 brown U1 black V1 blue W1 brown U2 green V2 white W2 yellow TOP 2x gray PE green yellow Item no 16617 5 9970 ENU Change 238450 Approved 2...

Page 10: ...FUNCTIONS POSSIBLE CAUSES AND REMEDIES Do not perform any repairs on your device Send the device to ebm papst for repair or replacement WARNING Live terminals and connections even with device switched...

Page 11: ...astening the protective earth terminal Visual inspection At least every 6 months Fasten Insulation of cables for damage Visual inspection At least every 6 months Replace cables Impeller for wear depos...

Page 12: ...ires are made of similar materials and are therefore to be treated in the same manner The materials concerned are as follows Miscellaneous insulators used in the terminal box Power cables Cables for i...

Reviews: