ebm-papst R2D225-AV02-14 Operating Instructions Manual Download Page 7

Operating instructions

R2D225-AV02-14

Translation of the original operating instructions

4.4 Connection screen

Δ

Delta connection

Y

Star connection

L1

black

L2

blue

L3

brown

U1

black

V1

blue

W1

brown

U2

green

V2

white

W2

yellow

TOP

2xgrey

PE

green/yellow

Item no. 12148-5-9970 · Revision 76115 · Release 2012-02-13 · Page 7 / 9

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Summary of Contents for R2D225-AV02-14

Page 1: ...m Only trained and authorised specialist personnel are permitted to transport unpack assemble operate or maintain the device or to use it in any other manner 1 3 Basic safety rules 1 1 3 Basic safety...

Page 2: ...ll WARNING Rotating device Long hair loose items of clothing and jewellery could become entangled and pulled into the device You could be injured Do not wear any loose clothing or jewellery while work...

Page 3: ...the following ways is particularly prohibited and may cause hazards Operating the device with an imbalance e g caused by dirt deposits or icing Moving air that contains abrasive particles Moving highl...

Page 4: ...line Dipotherm 0 5mm 9x brass lead tips crimped 2 Accessory part Inlet nozzle 96358 2 4013 not included in the standard scope of delivery 3 Depth of screw max 5 mm Item no 12148 5 9970 Revision 76115...

Page 5: ...protection IP 44 Depending on installation and position Insulation class F Humidity class F1 1 Mounting position Any Condensate discharge holes None Operation mode S1 Motor bearing Ball bearing Touch...

Page 6: ...n follow the basic principles in accordance with EN 61800 5 1 The protective earth must have a cross section equal to or greater than the outer conductor cross section We recommend the use of 105 C ca...

Page 7: ...Star connection L1 black L2 blue L3 brown U1 black V1 blue W1 brown U2 green V2 white W2 yellow TOP 2xgrey PE green yellow Item no 12148 5 9970 Revision 76115 Release 2012 02 13 Page 7 9 ebm papst Mu...

Page 8: ...er failure Danger of injury Keep out of the danger zone of the device When working on the device switch off the mains supply voltage and secure the latter from being switched on again Wait until the d...

Page 9: ...e device Check the device for damage to blades and housing Visual inspection At least every 6 months Replacement of the device Mounting the connection lines Visual inspection At least every 6 months F...