ebm-papst R2D220-AC16-17 Operating Instructions Manual Download Page 4

Operating instructions

R2D220-AC16-17

Translation of the original operating instructions

3. TECHNICAL DATA

3.1 Product drawing

All dimensions in mm.

1

Cable PFA 6G, 6x crimped splices

2

Accessory part: Inlet ring 09609-2-4013, not included in scope of delivery

3

Max. clearance for screw 5 mm

Item no. 12075-5-9970 · ENU · Change 230069 · Approved 2021-04-06 · Page 4 / 11

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Summary of Contents for R2D220-AC16-17

Page 1: ...and otherwise used by suitably qualified trained and authorized technical staff Only authorized specialists are permitted to install the device to carry out a test run and to perform work on the elect...

Page 2: ...ntal contact Before working on the system machine wait until all parts have come to a standstill WARNING Rotating device Long hair and dangling items of clothing jewelry and the like can become entang...

Page 3: ...prohibited and could be hazardous Operating the device in an unbalanced state e g due to dirt deposits or ice formation Resonant operation operation with severe vibration This also includes vibration...

Page 4: ...Cable PFA 6G 6x crimped splices 2 Accessory part Inlet ring 09609 2 4013 not included in scope of delivery 3 Max clearance for screw 5 mm Item no 12075 5 9970 ENU Change 230069 Approved 2021 04 06 Pag...

Page 5: ...regard to cyclic speed loads note that the rotating parts of the device are designed for a maximum of one million load cycles If you have special questions consult ebm papst for support Use the devic...

Page 6: ...with an all pole disconnection switch 4 2 1 Requirements Check whether the information on the nameplate matches the connection data Before connecting the device make sure the power supply matches the...

Page 7: ...otor protection the motor can overheat and suffer damage Connect the thermal overload protector installed in the winding The motor is provided with a thermal overload protector TOP Always check that t...

Page 8: ...1 Counterclockwise operation L1 V1 blue L2 U1 black L3 W1 brown 2 Clockwise operation L1 U1 black L2 V1 blue L3 W1 brown PE green yellow TOP implemented thermal overload protector 2x gray Item no 120...

Page 9: ...LFUNCTIONS POSSIBLE CAUSES AND REMEDIES Do not perform any repairs on your device Send the device to ebm papst for repair or replacement WARNING Live terminals and connections even with device switche...

Page 10: ...least every 6 months Fasten Fastening the protective earth terminal Visual inspection At least every 6 months Fasten Insulation of cables for damage Visual inspection At least every 6 months Replace c...

Page 11: ...aterials and are therefore to be treated in the same manner The materials concerned are as follows Miscellaneous insulators used in the terminal box Power cables Cables for internal wiring Electrolyti...