3. TECHNICAL DATA

3.1 Product drawing

All dimensions in mm.

1

Cable AWG20, 4 x crimped splices

2

Accessory part: inlet ring 97512-2-4013 not included in scope of delivery

3

Max. clearance for screw 6 mm

4

6 slots 7x12

Item no. 50310-5-9970 · ENU · Change 243693 · Approved 2022-09-06 · Page 4 / 10

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Summary of Contents for R1G310-AA19-52

Page 1: ...ated maintained and otherwise used by suitably qualified trained and authorized technical staff Only authorized specialists are permitted to install the device to carry out a test run and to perform w...

Page 2: ...ecure the device against accidental contact Before working on the system machine wait until all parts have come to a standstill WARNING Rotating device Long hair and dangling items of clothing jewelry...

Page 3: ...hazardous Operating the device in an unbalanced state e g due to dirt deposits or ice formation Resonant operation operation with severe vibration This also includes vibration transmitted to the fan...

Page 4: ...WG20 4 x crimped splices 2 Accessory part inlet ring 97512 2 4013 not included in scope of delivery 3 Max clearance for screw 6 mm 4 6 slots 7x12 Item no 50310 5 9970 ENU Change 243693 Approved 2022 0...

Page 5: ...ot be visible after installation Approval UL 1004 1 CSA C22 2 No 77 Use the device in accordance with its degree of protection Information on surface quality The surfaces of the products conform to th...

Page 6: ...nd has no disconnecting switch Only connect the fan to circuits that can be switched off with an all pole disconnection switch When working on the fan secure the system machine in which the fan is ins...

Page 7: ...ower supply 24 VDC maximum ripple 3 5 1 2 PWM lin yellow PWM lin control input 0 10 V 1 3 Tach white Tach output 3 pulses per revolution Isink max 10 mA 1 4 GND blue Reference ground Item no 50310 5 9...

Page 8: ...er 5 Maintenance malfunctions possible causes and remedies 4 7 Switching off the device Switching off the device during operation Switch off the device via the control input Do not switch the motor e...

Page 9: ...Replacement of device Fastening the cables Visual inspection At least every 6 months Fasten Insulation of cables for damage Visual inspection At least every 6 months Replace cables Impeller for wear d...

Page 10: ...insulating materials on the product in cables and wires are made of similar materials and are therefore to be treated in the same manner The materials concerned are as follows Miscellaneous insulator...

Reviews: